ExHauStInG
The dryer shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a concealed space of a
building.
Exhausting the dryer to the outside will prevent large amount of lint and moisture from being blown into the room.
In the United States:
•
All dryers must be exhausted to the outside.
•
The required exhaust duct is 4 inches (10.2 cm) in diameter.
•
Use only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the
manufacturer and that comply with the Outline for Clothes Dryer Transition Duct, Subject 2158A shall be
used.
•
See “Ducting Requirements” in installing your dryer section for the maximum duct length and number of
bends shall be used.
•
The total length of flexible metal duct shall not exceed 2.4 m.
•
Do not assemble the duct with screws or other fastening means that extend into the duct and catch lint
In Canada:
•
All dryer must be exhausted to the outside.
•
The exhaust duct should be 4 inches (10.2 cm ) in diameter.
•
Use only those foil-type flexible ducts, if any, specifically indentified for use with the appliance
by the manufacturer shall be used.
•
See “Ducting Requirements” in installing your dryer section for the maximum duct length and
number of bends.
•
The total length of flexible metal duct shall not exceed 2.4 m.
•
Do not assemble the duct with screws or other fastening means that extend into the duct
and catch lint.
Outside the U.S. and Canada:
•
Refer to the local codes.
You must exhaust the dryer to the outside to reduce the risk of fire when you install the
dryer in an alcove or closet.
NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT.
If your existing ductwork is plastic, non-metal, or combustible, replace it with metal.
Use only a metal exhaust duct that is non-flammable to ensure containment of exhaust air,
heat, and lint.
6 in. *
(15.2 cm)
1 in.
(2.5 cm)
84.6 in.
(215 cm)
30 in.
(76.2 cm)
* required spacing
** External exhaust elbow requires
additional space.
Required Dimensions for Installation With Stacking Kit (Model No.: SKK-BB)
Warning
01 installing your dr
yer
DV9100HA-DC68-03170K-12-EN.indd 11
2018/11/19 14:14:31
Содержание DV56H9100EV
Страница 41: ...memo DV9100HA DC68 03170K 12 EN indd 41 2018 11 19 14 14 38 ...
Страница 42: ...memo DV9100HA DC68 03170K 12 EN indd 42 2018 11 19 14 14 38 ...
Страница 43: ...memo DV9100HA DC68 03170K 12 EN indd 43 2018 11 19 14 14 38 ...
Страница 85: ...mémo DV9100HA DC68 03170K 12 CFR indd 41 2018 11 19 14 38 40 ...
Страница 86: ...mémo DV9100HA DC68 03170K 12 CFR indd 42 2018 11 19 14 38 40 ...
Страница 87: ...mémo DV9100HA DC68 03170K 12 CFR indd 43 2018 11 19 14 38 40 ...
Страница 129: ...comentarios DV9100HA DC68 03170K 12 MES indd 41 2018 11 19 14 47 10 ...
Страница 130: ...comentarios DV9100HA DC68 03170K 12 MES indd 42 2018 11 19 14 47 10 ...
Страница 131: ...comentarios DV9100HA DC68 03170K 12 MES indd 43 2018 11 19 14 47 10 ...