Installation requirements
English
11
Ducting requirements
Recommended
Use only for short-run installation
Weather hood
type
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Metallic
flexible*
Rigid
Metallic
flexible*
0
80 ft. (24.4 m)
41 ft. (12.4 m)
74 ft. (22.6 m)
33 ft. (10.1 m)
1
68 ft. (20.7 m)
37 ft. (11.2 m)
62 ft. (18.9 m)
29 ft. (8.8 m)
2
57 ft. (17.4 m)
33 ft. (10.1 m)
51 ft. (15.5 m)
25 ft. (7.6 m)
3
47 ft. (14.3 m)
29 ft. (8.8 m)
41 ft. (12.5 m)
21 ft. (6.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
DV8700K-03170T-00_EN (US)_151130.indd 11
2015-11-30 12:26:41
Содержание DV50K8600E
Страница 1: ...Dryer User manual DV50K8600E G DV8700K 03170T 00_EN US _151130 indd 1 2015 11 30 12 26 40 ...
Страница 55: ...Memo DV8700K 03170T 00_EN US _151130 indd 55 2015 11 30 12 26 52 ...
Страница 57: ...Sèche linge Manuel d utilisation DV50K8600E G DV8700K 03170T 00_CFR US _151201 indd 1 2015 12 01 1 15 09 ...
Страница 111: ...Mémo DV8700K 03170T 00_CFR US _151201 indd 55 2015 12 01 1 15 20 ...
Страница 113: ...Secadora Manual del usuario DV50K8600E G DV8700K 03170T 00_MES US _151201 indd 1 2015 12 01 6 58 46 ...
Страница 167: ...Notas DV8700K 03170T 00_MES US _151201 indd 55 2015 12 01 6 58 57 ...