CLOTHES DRYER

Technical Information

CAUTION

All safety information must be follwed as provided in Service Manual of 
DV50F9A6E(G)*/DV50F9A7E(G)*/DV50F9A8E(G)*..

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer 
before servicing, unless testing requires power.

Code No. : DC68-03171D_EN

• 

Due to possibility of personal injury or property damage, always contact an authorized 

technician for servicing or repair of this unit.

• 

Refer to Service Manual (DV50F9A6E(G)*/DV50F9A7E(G)*/DV50F9A8E(G)*) for detailed 

installation, operating, testing, troubleshooting, and disassembly instructions.

F900A DRY_DV50F_TECH MANUAL_DC68-03171D_EN(邀请翻译成法语).indd   1

2013-1-21   13:55:29

Содержание DV50F9A7EV

Страница 1: ... to dryer before servicing unless testing requires power Code No DC68 03171D_EN Due to possibility of personal injury or property damage always contact an authorized technician for servicing or repair of this unit Refer to Service Manual DV50F9A6E G DV50F9A7E G DV50F9A8E G for detailed installation operating testing troubleshooting and disassembly instructions F900A DRY_DV50F_TECH MANUAL_DC68 0317...

Страница 2: ...iseconds Check for Loose or open wire terminals in Door Sense circuit bE2 Invalid state of key circuit short for 30 secs Check for Display PCB key circuit short or not FE Invalid power source Frequency Check for Not using regular power source frequency Invalid power frequency sense circuit AE Electronic Control Problem Communication Error Check for Check PCB and Wire harness Replace PCB Et Invalid...

Страница 3: ...nfluenced Sensor Bar Touch Data Mode Definition of Sensor Bar Touch Data Mode This action will put the dryer into sensor bar touch data mode Dryer will display Sensor Bar data This mode is default mode of entering service mode How to Enter With Power On pressing Mixed Load Bell and Temp Keys for 3 seconds Cycle Count Mode Definition of Cycle Count Mode This mode is to bring up the total number of ...

Страница 4: ...in this mode Display Mode ID will be decreased Converting C F Celsius C 30 10 10 30 50 70 F 9 5C 32 Fahrenheit F 22 14 50 86 122 158 System Check Mode Definition of System Check Mode t2 will display System Check Mode t2 mode Progress Function Performed Start Pause Motor CW Relay On Heater Relay On Heater Relay Off Motor CW Relay Off How to Enter While in Power Off pressing the Dry Level Power keys...

Страница 5: ...ce of the human body and dryer by contacting the power supply plug when the work contacting to PCB is executed 2 As the P C B assembly is designed for no trouble do not replace the P C B assembly by the wrong diagnosis and follow the procedure of the trouble diagnosis when the micom is not operated normally ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock personal injury or deat...

Страница 6: ...or protector normal If above points are not found the PCB assembly is out of order Replace it 5 Blows fuses or trips circuit breaker Gas Model During ignition the dryer will draw X amps With the burner ON the dryer will draw X amps If the dryer is drawing amperages above this then the house wiring fuse box or circuit breaker is suspected to be at fault Igniter harness loose and shorted to base Inc...

Страница 7: ...haust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower impeller bound check for foreign material in blower area Customer overloading dryer Check clothing labels for fabric content and cycle selected Clothes too wet due to insufficient spin out by washer...

Страница 8: ...nity replace thermostat 2 Heater resistance 10 Ω If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch Off Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch On Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Vent Sensing Thermistor Resistance 238 23K Ω 25 77 Motor Elect...

Страница 9: ...diant sensor Igniter 101D Resistance value 40 400 Ω If resistance is infinite replace Igniter Gas Valve 25M01A Valve 1 2 Resistance value about 1 2K Ω Valve 1 3 Resistance value about 0 5K Ω Valve 4 5 Resistance value about 1 2K Ω If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 Ω If resistance is infinity replace Thermostat F900A DRY_DV50F_TECH MANUAL_...

Страница 10: ... laundry Approx 190Ω 10 with wet clothes Cycling Thermistor 1 Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6 Approx 10 KΩ at 25 C 77 F Cycling Thermistor 2 Disconnect harness and test Yellow wire Pin 2 to White wire Pin 7 CN4 Approx 238 23 KΩ at 25 C 77 F CN1 1 AC Power Port 2 Door Detection Sensor 3 Motor Switch Sensor RY7 Heater Relay Switch RY5 Motor Relay Switch RY2 RY3 CN5 Stea...

Страница 11: ...ted strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire 1 Remove the External ground connector screw 2 Connect the ground wire green or unwrapped of the power cord to the external ground connector screw If you want to connect B Green or bare copper wire of power cord to the Neutral Post without assembling with A cabin...

Страница 12: ... DIAGRAM WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power F900A DRY_DV50F_TECH MANUAL_DC68 03171D_EN 邀请翻译成法语 indd 12 2013 1 21 13 55 35 ...

Страница 13: ... sauf si le test nécessite sa mise sous tension Code n DC68 03171D_CFR En raison des risques de blessure ou de dommages matériels existants demandez toujours à un technicien qualifié d effectuer les opérations d entretien ou de réparation de l appareil Reportez vous au manuel de réparation DV50F9A6E G DV50F9A7E G DV50F9A8E G pour connaître les consignes d installation d utilisation de test de dépa...

Страница 14: ...u niveau du circuit du capteur du hublot bE2 État non valide de court circuit principal pendant 30 secondes Diagnostic possible Circuit principal de la carte de circuit im primé de l affichage court circuité ou non FE Fréquence de source d alimen tation non valide Diagnostic possible Utilisation d une fréquence d alimentation incorrecte Circuit du capteur de fréquence d alimen tation endommagé AE ...

Страница 15: ...abli Même si vous passez en mode de réparation le cycle de fonctionnement n est pas affecté Mode de données du capteur Définition du mode de données du capteur Cette action met le sèche linge en mode de données du capteur Le sèche linge affiche les données du capteur Ce mode est le mode par défaut pour passer en mode de réparation Pour sélectionner ce mode Avec l appareil sous tension appuyez sur ...

Страница 16: ...ustDown Diminuer est actionné en ce mode l identifiant du mode d afficha ge est diminué Convertir les C F Celsius C 30 10 10 30 50 70 F 9 5C 32 Fahrenheit F 22 14 50 86 122 158 Mode de contrôle système Définition du mode de contrôle système t2 s affiche Mode de contrôle système mode t2 Fonction de progression activée Départ Pause Relais moteur CW activé Relais résistance activée Relais résistance ...

Страница 17: ...elié à la terre ou éliminez la différence de potentiel de votre corps et du sèche linge en touchant la prise d alimentation avant de travailler sur la carte de circuit imprimé 2 La carte de circuit imprimé étant un composant résistant ne la remplacez pas suite à un diagnostic erroné et respectez la procédure de diagnostic des problèmes lorsque le micom ne fonctionne pas correctement ALIGNEMENTS ET...

Страница 18: ...or enroulement du stator génératrice La protection du moteur est elle normale Si aucun des points ci dessus n est défaillant la carte de circuit imprimé est défectueuse Remplacez la 5 Fait griller les fusi bles ou déclenche le disjoncteur modèle à gaz Lors de l allumage le sèche linge consomme X A Lorsque le brûleur est allumé le sèche linge consomme X A Si la consom mation du sèche linge est supé...

Страница 19: ...uit d évacuation est trop long trop coudé trop flexible La prise d air du sèche linge est mauvaise La vitesse du tambour est incorrecte La courroie du tambour est mal fixée La turbine du ventilateur est bloquée Vérifiez qu il n y a pas de corps étrangers au niveau du ventilateur L utilisateur a surchargé le sèche linge Vérifiez les étiquettes des vêtements et le cycle sélectionné Les vêtements son...

Страница 20: ...Résistance de l élément chauffant 10 Ω Si la résistance est infinie remplacez l élé ment chauffant Mesurez la résistance des bornes suivantes 1 Interrupteur du hublot arrêt Borne COM NC 1 3 1Ω Borne COM NO 1 2 Ω 2 Interrupteur du hublot actionné Borne COM NC 1 3 Ω Borne COM NO 1 2 1 Ω Commutateur d arrêt de la courroie Manette ouverte valeur ohmique 1 Ω Manette actionnée valeur ohmique Ω Détecteur...

Страница 21: ...teur radiant Allumeur 101D Valeur ohmique 40 à 400 Ω Si la résistance est infinie remplacez l allumeur Soupape à gaz 25M01A Soupape 1 2 valeur ohmique 1 2 KΩ environ Soupape 1 3 valeur ohmique 0 5 KΩ environ Soupape 4 5 valeur ohmique 1 2 KΩ environ Si la résistance est infinie remplacez la sou pape Thermostat régulateur 60T21 230F 50F Valeur ohmique 1 Ω Si la résistance est infinie remplacez le t...

Страница 22: ...ouillé Thermostat de cyclage 1 Débranchez le faisceau et testez le fil bleu au niveau de la broche 3 et le fil rouge au niveau de la broche 6 Environ 10 KΩ à 25 C 77 F Thermostat de cyclage 2 Débranchez le faisceau et testez le fil jaune au niveau de la broche 2 et le fil lanc au niveau de la broche 7 CN4 Environ 238 23 KΩ à 25 C 77 F CN1 1 Port d alimentation CA 2 Capteur de la porte 3 Capteur de...

Страница 23: ...r de tension 1 9 cm homologué UL D Vis centrale argentée du bornier E Fil de terre neutre vert jaune F Fil neutre blanc ou central 1 Retirez la vis du connecteur de terre externe 2 Reliez le fil de terre vert ou sans habillage du cordon d alimentation au connecteur à vis de terre externe Pour brancher B fil vert ou en cuivre dénudé du cordon d alimentation à la borne neutre sans l assembler à A mi...

Страница 24: ... AVERTISSEMENT Afin d éviter tout risque d électrocution légère ou mortelle débranchez le sèche linge avant de le réparer sauf si le test nécessite sa mise sous tension F900A DRY_DV50F_TECH MANUAL_DC68 03171D_CFR indd 12 2013 1 21 13 56 46 ...

Отзывы: