5
No
Problem
What To Do
1
Will Not Start or Run
•
All wires are hooked up to their corresponding terminals.
•
Dryer is plugged in.
•
Blown fuse or circuit breaker.
•
Door switch functional...door closed. Check for error code 3 (See
Table for codedefinition).
•
Start/Pause rotary selector dial functional.
•
Control Board operational.
•
Belt off or broken and Belt Cut-off Switch operates.
•
Drive motor functional.
•
Check motor winding resistance: 2.88ohms between pin #3 and 4,
3.5ohms between pin #4 and 5.
2
Motor runs/ tumbler
will not turn
•
Belt off or broken/damaged.
•
Idler tension spring too weak or stretched.
•
Idler pulley jammed or stuck.
3
Runs a few minutes
and then stops
•
Lint buildup around drive motor.
•
Low voltage present.
•
Blower impeller blocked in blower housing.
•
Drive motor - start switch contacts stuck closed.
4
Blows fuses or trips
circuit breaker
•
Is the belt connected well?
•
Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)
•
Is the motor protector normal?
•
If above points are not found, the PCB assembly is out of order.
Replace it.
5
Blows fuses or trips
circuit breaker (Gas
Model)
•
During ignition the dryer will draw X amps. With the burner ON, the
dryer will draw X amps. If the dryer is drawing amperages above this,
then the house wiring, fuse box or circuit breaker is suspected to be
at fault.
•
Igniter harness loose and shorted to base.
•
Incorrect wiring or wire shorted to ground.
•
Drive motor winding shorting to ground.
6
Will not heat (motor
runs)
Open heating element.
•
Hi-Limit trips easily or is open.
•
Regulating thermostat trips easily or is open.
•
Membrane switch open.
•
Check Thermistor.
7
Will Not Dry Gas
Model Poor Gas
Ignition
When the dryer is operated on a heat setting, the igniter should be
energized and burner shall fire within 45 seconds at 120 VAC. The failure
of a component in this system will usually be indicated by one of three
symptoms:
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Technical_information-03382A_EN_131209.indd 5
2013-12-09 �� 5:37:31