38 _ PCB Diagram
5. PCB DIAGRAM
5-1. MAIN PCB
This Document can not be used without Samsung’s authorization.
Location
Part No.
function
1
CN1
AC CONNECTION
CONNECTOR
Supplies AC power to the PBA
2
CN2
SUB PBA COMMUNICATION
CONNECTOR
The connector that controls communications with the Sub PBA
corresponding to the Display.
3
CN3
MICOM FLASH CONNECTOR
The connector that writes software onto the MICOM.
4
CN4
SENSOR CONNECTION
CONNECTOR
Connects the temperature sensor in order to detect the
temperature of the heater.
5
CN5
VALVE CONNECTION
CONNECTOR
It is connected to the steam Valve(Steam Models Only) and the
Lamp of the Drive Block and controls the ON/OFF signal.
Location
Part No.
function
6
CN6
SET GROUND CONNECTION
CONNECTOR
The connector connecting the Dryer Set and the ground of the
PBA
7
RY5
MOTOR OPERATION RELAY
The relay that turns the Main Motor and off.
8
RY6
HEATER2 OPERATION RELAY
The relay that turns the Heater2 on and off.
9
RY7
HEATER1 OPERATION RELAY
The relay that turns the Heater1 on and off.
1
8
2
3
4
7
5
6
9