18_
installing your dryer
4-WIRE system connections
1.
Remove the center terminal block screw.
2.
Connect the ground wire (green or unwrapped) of the
power cord to the external ground conductor screw.
3.
Connect the neutral wire (white or center wire) of the
power cord and the appliance ground wire (green with
yellow stripes) under the central screw of the terminal
block.
4.
Connect the other wires to the outer terminal block
screws. Tighten the screws.
5.
Tighten the strain relief screws.
6.
Insert the tab of the terminal block cover into your dryer’s rear panel slot.
Secure the cover with a hold-down screw.
1. External ground connector
2. Green or bare copper wire of power cord
3. 3/4 in. (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Grounding wire (green/yellow)
6. Neutral wire (white or center wire)
7.
With a level, check your dryer and make necessary adjustments to the leveling legs.
8.
At this time, make sure all gas connections (on gas models), exhaust and electrical connections are
complete. Plug in your dryer, and check operation by using the checklist below.
9.
(GAS MODELS ONLY) - DV338AGW, DV338AGB
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat
setting will purge the line. If the gas does not ignite within 5 minutes, turn your dryer off and wait 5
minutes. Be sure the gas supply to your dryer has been turned on. In order to confirm gas ignition,
check the exhaust for heat.
FINAL INSTALLATION CHECKLIST
Dryer is plugged into an electrical outlet and is properly grounded.
Exhaust ductwork is hooked up and joints are taped.
Plastic flexible duct is NOT used.
Used rigid or stiff-walled flexible metal vent material.
Dryer is level with all legs sitting firmly on the floor.
Gas models – gas is turned on with no gas leaks.
Start your dryer to confirm that it runs, heats, and shuts off.
installing your dryer
DV339AEW-02571B_EN.indd 18