background image

Sensor Bar Touch Data Mode

   

How to Enter:  
Power on dryer, open door and press in door switch. 
Start dryer tumbling. Press Temp + Signal for 3 sec. 
Touch both sensor bars with wet cloth, sensor hit numbers 
show in display.  
Note: Test mode subject to change without notice 

Cycle Count Test Mode

   

How to Enter:

                                                                         

Press Temp + Signal Keys for 3 sec during  Power On 
State.                                                                          
Press Signal for 3 seconds (until beep)                                                                                                                     
Note: Test mode subject to change without notice 

Software Version Test Mode

   

How to Enter:

                                                                         

Press Temp + Signal Keys Keys for 3 sec during  Power 
On State.                                                                    Press 
Temp key for 3 seconds (until beep)                                                       
Note: Test mode subject to change without notice 

Temperature Test Diagnostic Mode

 

How to Enter:

 

Press Adjust Time Up + Down Keys for 3 sec during  
Power On State.                                                          
Press Adjust Time Up and it  will display the temperature 
in Celsius.

                                                                                

Compare vent temp to drum temp to see air flow.        

This can be with just power on or dryer running.

 

Gas Valve Testing  

Unplug connectors and test valve terminals

 

(its numbering is from the front terminal.) 

Check across terminals #1 and #3 (Booster Coil).                550 

 

Check across terminals #1 and #2 (Holding Coil).               1350 

  

Check across terminals #2 and #3 (Both coils in series).   1900 

 

Check across terminals #4 and #5 (Secondary Coil).          1300 

 

Dryer continues to run after cycle completed 

Wrinkle Prevent option provides approximately 90 minutes (20 continuous and 70 intermittent) of tumbling in 
unheated air at the end of the cycle to reduce wrinkling. Press the Wrinkle Prevent button to activate or deac-
tivate this feature. The indicator light above the pad will illuminate when Wrinkle Prevent is selected. Chasing 
lights appear in the display when the Wrinkle Prevent option is selected. The load is dry, and can be removed 
at any time during the Wrinkle Prevent cycle.

 

SUBJECT: Dryer belt slides off the pulley when 
manually rotated counter-clockwise (ccw) 

SYMPTOM: The dryer drum will not turn. On occa-
sions, the customer will rotate the drum counter 
clockwise (CCW) to check for any remaining 
clothes left in the dryer drum. By rotating the drum 
CCW, the idler arm may shift causing the belt to 
slide off the pulley. 
SOLUTION: To prevent the dryer belt from sliding 
off the pulley, the pulley has been redesigned. 
The Outside Diameter has been changed from 
22mm to 27mm. 

New  

DC81-00220A

 

Special Test Mode: 



While in Power Off, pressing the Dry Level + Power keys simultaneously will put the dryer into the System 
Check mode.                         “ t2 “ will display. 



System Check Mode Progress 



t2 mode Function Performed Start/Pause Motor (CW) Relay On 

 Heater Relay On 

 Heater Relay Off 

 

Motor (CW) Relay Off (Circulation)                                                                                                                                    

 

Make sure the idler pulley & the motor pulley are in 
a straight line, bend if needed 

Содержание DV330AEW

Страница 1: ...ce Dryer Thermistor Open Sensed The Thermistor resistance is very high Check for Clogged lint screen Restricted vent system Thermistor resistance dO dE Door Open Running the dryer with door open Check for Loose or open wire terminals in Door Sense circuit FE Power source frequency Error Invalid power source Frequency Check for Non Utility power supply dF Door Circuit Failure Invalid state for more...

Страница 2: ...CN4 RY 6 CN6 RY 5 CN7 CN5 CN1 ...

Страница 3: ...CN4 RY 6 CN6 RY 5 CN7 CN5 CN1 ...

Страница 4: ...1 Blk Relay 6 1 Gas Hi Limit T Stat Blu 2 120vac L1 Blk Relay 6 1 Heater Cut Off T Stat Blu 2 120vac L1 Blk CN5 1 Lamp Vio CN6 1 Earth Ground Grn CN4 3 6 Thermistor Blu Red 4 5 Moisture Sensor Pnk Org CN2 Sub PCB Display 5 4 5VDC Wht Pnk 6 4 15VDC Red Pnk CN7 1 Motor 6 Blk 2 Door Sw Blu New Version of Blower Housing it may be necessary to separate the harness wrap on replacement housing Please mai...

Страница 5: ...Ω Dryer continues to run after cycle completed Wrinkle Prevent option provides approximately 90 minutes 20 continuous and 70 intermittent of tumbling in unheated air at the end of the cycle to reduce wrinkling Press the Wrinkle Prevent button to activate or deac tivate this feature The indicator light above the pad will illuminate when Wrinkle Prevent is selected Chasing lights appear in the displ...

Страница 6: ...r on start dryer read voltage between RY6 Blue wire and CN6 Green wire Reading of 120VAC means a proper operating heater circuit 0VAC means open in circuit To test thermostats use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...

Страница 7: ...age reading means Main PCB is defective See page 4 for Main PCB layout for testing Testing Motor circuit With power off read resistance between RY5 Brown and CN7 Blue Resistance reading of good motor circuit is about 1 9Ω To test thermostat and switch use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...