6. Diagnostics
6-1. Pre p a r a t i o n s
6-1-1. Personal
Computer
(With 486 CPU or higher)
6-1-2. RS232 Cable for communication
6-1-3. OS (Windows
3.1 or higher)
6-2. Setup
6-2-1. Connect
the 9 pin connector(RS232
Null Modem cable) of IRD (on the
back panel) to the serial port of the PC or terminal
(115200,N,8,1)
6-2-2. Turn on the PC
6-2-3. Select Winfile
manager
to execute
BskybTerm.
6-2-4. Configurate
the Port and Baudrate
as below;
Port
: Select to COM port currently
used.
Baudrate
: 115200
6-2-5. Turn on the STB.
For normal operation
the following
messages
will display
on the PC screen,
.
.
.
set LNB freq (lo 9750000,
hi 10600000,
sw 11700000)
tv status 2!
Set TV to CBVS
Send Ok
#CONTROL[running]
unknown
control
error=0x10
new scan parameters
fixed parameters
invalid
- IGNORED
new scan request
scan: freq 11778000,
sr 27500000,
pol 1 (0=H, 1=V), direction
0
tune 1178000KHz,
27500Ksps
Auto
scan lock
Welcome
to Test tool V1.00
Tool>