background image

E-

15

Bucket Full Indicator

When the water bucket is full, the Bucket Full indicator will light up and the 
unit will power off.

1

Once the unit has powered off. 

 Please unplug the power cord for safety.  

 When the bucket full indicator is on, you will not be able to operate the unit.

2

Hold the holes on both sides of the water bucket, and slide out.

3

Hold the handle on the top of the water bucket and dispose of the water. 

4

Slide the empty water bucket back into place. 

 When the Bucket Full indicator is off, push the ON/OFF button to select 

     the operating mode you wish to use.    

 If the water bucket is not empty or incorrectly inserted, the Bucket Full  

     indicator will come on and the product will not operate.

³ýʪ»ú-E.indd   15

2007-10-18   10:11:32

Содержание DED30EL8

Страница 1: ...e 11 Selecting the Continuous Run Mode 12 Selecting the Self Dry Mode 13 Selecting the Off Timer Mode 14 RECOMMENDATIONS FOR USE Bucket Full Indicator 15 Setting up the Drain Hose Connector 16 Cleaning the Dehumidifier 17 Troubleshooting Guide 19 Technical Specifications 19 Temperature Ranges 19 ýʪ ú E indd 2 2007 10 18 10 10 43 ...

Страница 2: ...the unit is flooded please contact a service center page 20 Safety Precautions Thefollowingsafetyprecautionsareprovidedtoprotecttheusers safetyandpreventpropertydamage Makesuretoreadthefollowingandusethedehumidifierproperly Keepthisuser smanualinahandyplacesothatyoucanfinditwhenever youneedtoseeitafterreadingthismanualthoroughly WARNING This indicates the possibility of serious injury or death CAU...

Страница 3: ...he unit Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it Do not allow children to sit on top of the unit Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit When you need to dispose of the unit consult your dealer If pipes are removed incorrectl...

Страница 4: ...ll this unit in a place where the product may fall and become damaged To save energy disconnect the power cord when not using the dehumidifier Contact a Samsung service center if you need repair on the dehumidifier If strange noises are heard smoke blows out of the unit or there is a burning smell turn off the dehumidifier and contact a Samsung authorized service center Page 20 REGARDING POWER SOU...

Страница 5: ...midifier to maintain food pets plants or cosmetics Do not use excessive force when using the dehumidifier CAUTION Do not drink the water from the dehumidifier Do not let children sit on top of the dehumidifier Do not remove the water bucket while operating ýʪ ú E indd 6 2007 10 18 10 11 06 ...

Страница 6: ...water benzene thinner or alcohol directly onto the unit If the fan stops working turn the dehumidifier off and clean it Clean the air filter every 2 weeks Be sure to insert the air filter CAUTION Be careful when removing the water bucket There is a risk of water splashing when bucket is full ýʪ ú E indd 7 2007 10 18 10 11 15 ...

Страница 7: ... Component Main Unit Water Bucket Control Part for consistency Air Filter Handle Drain Hose Connector Drain Connector Hole Power Cord Drain Hole The design and shape are subject to change ýʪ ú E indd 8 2007 10 18 10 11 21 ...

Страница 8: ...ty Setting Display ord Continuous Run button Self Dry button On Off button OffTimer but ton Bucket Full indicator Humidity Setting Display Fan speed indicator Humidity display Operating display Self Dry indicator OffTimer indicator ýʪ ú E indd 9 2007 10 18 10 11 24 ...

Страница 9: ...ep procedures use three different symbols PRESS PUSH HOLD DOWN This product includes a power failure reset function When a power failure occurs do not operate the unit right away after the power comes back on When the power seems to be back to normal resume usage of the product If the power plug is removed while the unit is operating plugging in the power plug again will resume operation If the Of...

Страница 10: ...2 Please press the or buttons on the Humidity Control area to adjust the humidity The humidity level can be adjusted from 35 to 80 by pressing the or buttons The humidity adjusts in 5 increments Note If the location humidity level is below the set level the compressor won t start 3 Press the button to select the fan speed Result When pressing the button the Fan Speed will switch between Low and Hi...

Страница 11: ...un in humidity mode 1 Press the button to turn the unit on 2 Press the button Result will be displayed The fan Speed is set to On this setting humidity level is not adjustable Note The dehumidifier will stop when the Bucket Full indicator lights up For more information see page 15 ýʪ ú E indd 12 2007 10 18 10 11 26 ...

Страница 12: ... button Result Only the symbol will be displayed and the fan speed will automatically adjust to low The inside moisture of the unit is removed in 30 minutes In Self Dry mode the product will power off after 30 minutes 1 Press the button Result The symbol will be displayed and Self Dry mode will start Self Dry mode can be canceled by pressing the or button The inside moisture of the unit is removed...

Страница 13: ...ble in Continuous Run mode 2 Press the button Result You can select the off timer to shut off in 3Hr 6Hr or 12Hr Automatic Defrost Operation The humidifier has a defrost control that automatically senses frost build up on the evaporator coil During defrosting the fan will continue to run while the compressor is kept off 3 C 38 F ýʪ ú E indd 14 2007 10 18 10 11 29 ...

Страница 14: ... the unit 2 Hold the holes on both sides of the water bucket and slide out 3 Hold the handle on the top of the water bucket and dispose of the water 4 Slide the empty water bucket back into place When the Bucket Full indicator is off push the ON OFF button to select the operating mode you wish to use If the water bucket is not empty or incorrectly inserted the Bucket Full indicator will come on an...

Страница 15: ...ugh the Drain Connector Hole and connect it to the Drain Hole 4 Connect the Drain Hose to the Drain Hose Connector The Drain hose sold separately at participating retail stores An optional drain hose is available for purchase through Retail stores 5 Slide the water bucket back into place If the water bucket is incorrectly inserted the Bucket Full light will come on and the product will not operate...

Страница 16: ...too much dust please wash the air filter with warm water and dry it in the shade Please do not wrap the air filter when cleaning it 4 Insert the air filter 5 Slide the water bucket back into place If the water bucket is incorrectly inserted the Bucket Full indicator will go on and the product will not operate Note We recommend cleaning the air filter every 2 weeks If the unit is in an area where t...

Страница 17: ... it 3 Clean the water bucket with a warm damp soft cloth 4 Place the bucket cover back into place by pushing it down 5 Slide the water bucket back into place If the water bucket is incorrectly inserted the Bucket Full indicator will come on and the product will not operate Cleaning the Water Bucket ýʪ ú E indd 18 2007 10 18 10 11 55 ...

Страница 18: ...orrect low humidity 35 Check if there is too much dust on the filter Check if there is anything blocking the air flow Technical Specifications Temperature Ranges If the dehumidifier is used at Then Higher temperature The automatic protection feature may be triggered and the dehumidifier will stop Low temperature The heat exchanger may freeze and as a result some malfunction may occur Operation Tem...

Страница 19: ...rial or workmanship Labor to install the compressor during these existing four years is not included in the warranty All warranty repairs must be performed by a Samsung Authorized Service Centre Obligation of the Original Owner The original dated purchase receipt must be retained as proof of purchase and presented to the Authorized Service Centre before warranty services are rendered Exclusions of...

Страница 20: ...DEHUMIDIFIER DB98 28586A 1 F E USER SMANUAL DED30EL8 DED40EL8 DED45EL8 DED50EL8 DED65EL8 ýʪ ú E indd 21 2007 10 18 10 11 59 ...