5-4 High Voltage Capacitor

1. Check continuity of the capacitor with the meter set at the highest resistance scale.
2. Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9M.
3. A shorted capacitor will show continuous continuity.
4. An open capacitor will show constant 9M

.

5. Resistance between each terminal and chassis should read infinite.

5-5 High Voltage Diode

1. Isolate the diode from the circuit by disconnecting its leads.
2. With the ohm-meter set at the highest resistance scale, measure across the diode terminals. Reverse the

meter leads and read the resistance. A meter with 6V, 9V or higher voltage batteries should be used to
check the front-to back resistance of the diode (otherwise an infinite resistance may be read in both
directions). The resistance of a normal diode will be infinite in one direction and several hundred K

in the

other direction.

5-6 Main Relay and Power Control Relay

1. The relays are located on the PCB Ass'y. Isolate them from the main circuit by disconnecting the leads.
2. Operate the microwave oven with a water load in the oven. Set the power level set to high.
3. Check continuity between terminals of the relays after the start pad is pressed.

5-7 Adjustment of Primary Switch, Door Sensing Switch and Monitor Switch

1. When mounting Primary switch and Interlock

Monitor switch to Latch Body, consult the figure.

2. No specific adjustment during installation of

Primary switch and Monitor switch to the latch
body is necessary.

3. When mounting the Latch Body to the oven

assembly, adjust the Latch Body by moving it so
that the oven door will not have any play in it.
Check for play in the door by pulling the door
assembly. Make sure that the latch keys move
smoothly after adjustment is completed.
Completely tighten the screws holding the Latch
Body to the oven assembly.

4. Reconnect to Monitor switch and check the

continuity of the monitor circuit and all latch
switches again by following the components test
procedures.

5. Confirm that the gap between the switch

housing and the switch actuator is no more than
0.5mm when door is closed.

Door Open

Door Closed

Primary switch
Monitor switch
(COM-NC) Monitor
switch (COM-NO)
Door Sensing S/W

0


0

0
0

Primary Interlock Switch

Interlock
Monitor
Switch

Body Latch

Lever Door(B)

Door Sensing
Switch

Precaution

For continued protection against radiation hazard, replace parts in accordance with the wiring diagram and be sure to
use the correct part number for the following switches: Primary and secondary interlock switches, and the interlock
monitor switch (replace all together). Then follow the adjustment procedures below. After repair and adjustment, be
sure to check the continuity of all interlock switches and the interlock monitor switch.

Содержание CE2777R-S

Страница 1: ...ENTS MICROWAVE OVEN 1 Precaution 2 Specifications 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Trouble 7 Exploded Views and Parts List 8 PCB Diagrams 9 Schematic Diagrams Manual CE2777R S CE2777R ...

Страница 2: ...s and latches 5 evidence of dropping or abuse c Before turning on microwave power for any service test or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems s...

Страница 3: ...e their watches while repairing an MWO 11 To avoid any possible radiation hazard replace parts in accordance with the wiring diagram Also use only the exact replacements for the following parts Primary and secondary interlock switches interlock monitor switch 12 If the fuse is blown by the Interlock Monitor Switch Replace all of the following at the same time Primary door sensing switch and power ...

Страница 4: ...ure 1 1 2 The high voltage capacitor remains charged about 30 seconds after disconnection Short the negative terminal of the high voltage capacitor to to the oven chassis Use a screwdriver 3 High voltage is maintained within specified limits by close tolerance safety related components and adjustments If the high voltage exceeds the specified limits check each of the special components PRECAUTION ...

Страница 5: ...REQUENCY MAGNETRON COOLING METHOD OUTSIDE DIMENSIONS OVEN CAVITY DIMESIONS SHIPPING WEIGHT APPROX 99 MINUTES 230V 50Hz AC MICROWAVE 1 400W GRILL 1100W COMBI 2500W FROM 100 TO 850W IEC 705 TEST PROCEDURE 2 450MHz OM75PH 31 COOLING FAN MOTOR 489 W x 275 H x 415 D 305 W x 201 H x 322 D NET 16 0kg GROSS 17 5kg ...

Страница 6: ...oor Latches Ventilation Holes Glass Tray Light Safety Interlock Holes Coupler Door Guide Roller 357mm 489mm 200mm 275mm 415mm CLOCK SETTING DISPLAY AUTO REHEAT COOK SELECTION POWER LEVEL SETTING COMBI BUTTON START DIAL KNOB GRILL BUTTON AUTO POWER DEFROST BUTTON STOP CANCEL BUTTON ...

Страница 7: ...oes not hit any adjacent parts or it may be damaged NOTE2 When replacing the magnetron be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition 4 2 Replacement of High Voltage Transformer 1 Discharge the high voltage capacitor 2 Disconnect all the leads 3 Remove the mounting bolts 4 Reconnect the leads correctly and firmly PRECAUTION Servicemen ...

Страница 8: ...C to remove Door C Be careful when handling Door C because it is fragile 4 3 3 Removal of Key Door Spring Following the procedure as shown in the figure insert and bend a thin metal plate between Door E and Door A until you hear the tick sound 1 Insertion depth of the thin metal plate should be 0 5mm or les 4 3 4 Removal of Key Door Spring Remove pin hinge from Door E Detach spring from Door E and...

Страница 9: ...ate properly check if any other part such as the control circuit board blower motor or high voltage transformer is defective 4 5 Replacement of Drive Motor 1 Take out the glass tray guide roller and coupler from cavity 2 Turn the oven upside down to replace the drive motor 3 Remove a screw securing the drive motor cover 4 Disconnect all the lead wires from the drive motor 5 Remove screws securing ...

Страница 10: ...ver touch the control circult 2 Disconnect the connectors from the control circuit board 3 Remove screws securing the control box assembly 4 Remove the screw securing the ground tail of the keyboard 4 6 2 Remonal of Ass y P C B Assembly 1 Remove screws securing the control circuit board 2 Lift up the control circuit board from the Ass y control box SCREWS ASSY PCB ...

Страница 11: ... shorted magnetron 2 Isolate the magnetron from the circuit by disconnecting its leads 3 A continuity check across the magnetron filament terminals should indicate one ohm or less 4 A continuity check between each filament terminal and magnetron case should read open Primary Terminals Filament Terminals Secondary Terminal Magnetron Antenna Gasket Plate Cooling Fins PRECAUTION 1 High voltage is pre...

Страница 12: ...nd Monitor Switch 1 When mounting Primary switch and Interlock Monitor switch to Latch Body consult the figure 2 No specific adjustment during installation of Primary switch and Monitor switch to the latch body is necessary 3 When mounting the Latch Body to the oven assembly adjust the Latch Body by moving it so that the oven door will not have any play in it Check for play in the door by pulling ...

Страница 13: ...ure will cause a variance in the temperature rise Additional power test should be made if temperature rise is marginal NOTE 2 Output power in watts is computed by multiplying the temperature rise step 5 by a factor of 91 times the of centigrade temperature 5 9 Microwave Heat Distribution Heat Evenness The microwave heat distribution can be checked indirectly by measuring the water temperature rise...

Страница 14: ...t the highest power level 4 Set survey meter dual ranges to 2 450MHz 5 Using the survey meter and spacer cone as described above measure arnear the opening of magnetron the surface of the air guide and the surface of the wave guide as shown in the following photo but avoid the high voltage components The neading should be less than 4mW cm 2 5 12 Note on Measurement 1 Do not exceed the limited scal...

Страница 15: ...dure Replace PCB main Timer starts countdown but no microwave oscillation No heat while oven lamp and fan motor turn on 1 Off alignment of latch switches 2 Open or loose connection of high voltage circuit especially magnetron filament circuit NOTE Large contact resistance will bring lower magnetron filament voltage and cause magnetron to lower output and or intermittent oscillation 3 Defective hig...

Страница 16: ...ain Loud buzzing noise can be heard 1 Loose fan and fan motor 2 Loose screws on H V Transformer 3 Shorted H V Diode Tighten screws of fan motor Tighten screws of H V Transformer Replace H V Diode Turntable motor does not rotate 1 Open or loose wiring of turntable motor 2 Defective turntable motor Replace turntable motor Oven stops operation during cooking 1 Open or loose wiring of primary interloc...

Страница 17: ...4 MM27 MM28 MM67 MM52 MM06 MM171 MM05 MM55 MM26 MM61 MM68 MM109 MM60 MM57 MM17 MM08 MM09 MB01 MM07 MM25 MM59 MM21 MM18 MM19 MM20 MM64 MM03 MM32 MM10 MM88 MB05 MB03 MB03 MB02 MB04 MD04 MD06 MD05 MD11 MD14 MD191 MD03 MD02 MD24 MD10 MD01 MD07 MD19 MC13 MC142 MC141 MC31 MC27 MC143 MC01 MC03 MC06 MC07 MC15 MC10 ...

Страница 18: ...7 2 Main Parts List 0 0 ...

Страница 19: ...7 3 Control Parts List S N A SERVICE NOT ASSEMBLY 0 0 1 ...

Страница 20: ...7 4 Door Parts List 2 2 ...

Страница 21: ...7 5 Standard Parts List 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 2 ...

Страница 22: ...8 P C B Diagrams 8 1 P C B Diagrams ...

Страница 23: ...8 2 P C B Parts List 45 67 45 3 3 3 8 8 8 8 49 7 8 8 0 2 2 49 0 8 0 0 0 8 8 33 3 3 ...

Страница 24: ...9 Schematic Diagrams 9 1 Schematic Diagrams RED RED BRN BLK FA F HIGH VOLTAGE TRANSFORMER H V FUSE HIGH VOLTAGE CAPACITOR HIGH VOLTAGE DIODE TO CHASSI MAGNETRON RED RED ...

Отзывы: