. Electrical Characteristics

Absolute Maximum Ratings 

Symbol

 

Parameter

 

Min.

 

Max.

 

Unit

 

VIN 

DC supply voltage 

12

 

Power Consumption 

Parameter

 

Conditions

 

Min.

 

Nom.

 

Max.

 

Unit

 

Tx mode (Max current) 

TX Power 

5V, 0dBm(+/-5dB) Tx Power 

40 

mA 

Recommended Operating Conditions 

Symbol

 

Parameter

 

Conditions

 

Min.

 

Nom.

 

Max.

 

Unit

 

VIN 

DC supply voltage from HOST 

+4.5

+5

+13.2V

Top 

Operating temperature(Ambient) 

-20 

+

50

°C 

Environmental Characteristics 

Symbol

 

Parameter

 

Conditions

 

Min.

 

Max.

 

Unit

 

ESD 

Electro-static discharge voltage 

HBM 

-4K

+4K

Top 

Operating temperature 

-20 

+85

°C 

Tstg 

Storage temperature 

-30 

+85

°C 

Содержание CBAP210A

Страница 1: ...rsion 5 0 only supports 1 Mbps Supports Adaptive Frequency Hopping On chip support for serial peripheral interface master and slave modes Compact dimension 3 5 mm x 2 0 mm H max 4 8 mm Host Interfaces UART Interface RoHS compliant PCB Pattern antenna 5 60 dBi Number of channels 40 ch Applicable test standard FCC Part 15 Subpart C 15 247 Supply voltage range VCC 5V 4 5V 12V Power Consumption 200mW ...

Страница 2: ... TX Power 5V 0dBm 5dB Tx Power 40 mA Recommended Operating Conditions Symbol Parameter Conditions Min Nom Max Unit VIN DC supply voltage from HOST 4 5 5 13 2V V Top Operating temperature Ambient 20 50 C Environmental Characteristics Symbol Parameter Conditions Min Max Unit ESD Electro static discharge voltage HBM 4K 4K V Top Operating temperature 20 85 C Tstg Storage temperature 30 85 C ...

Страница 3: ...Range 2402 K 2MHz K 0 39 2402 2480 MHz Receiver Sensitivity PER PER 30 8 94 dBm RSSI Value TCR Value TCB RSSI Calibration Value 50 DUT RSSI Value TRC Value 20 RSSI TRC Value 20 30 70 Transmitter Output Power Max Tune up Average Power 1 0 dBm ICFT 150 150 kHz Frequency Drift 50 50 Drift rate 20 kHz 50us Frequency Deviation Avg payload sequence 00001111 225 275 kHz Max payload sequence 10101010 185 ...

Страница 4: ...e this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 4 FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body This transmitter must not be c...

Страница 5: ...e in the users manual This device complies with Part 15 of FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed L...

Страница 6: ...formed to keep at least 20cm separation with the antenna while this end product is installed and operated The end user has to be informed that the IC radio frequency exposure guidelines for an uncontrolled environment can be satisfied The end user has to also be informed that any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equ...

Отзывы: