- 5 -
4. Disassembly and Reassembly
Remove the magnetron including the shield case,
permanent magnet, choke coils and capacitors
(all of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron and
lamp.
2. Remove the air cover.
3. Remove screws securing the magnetron to the
wave guide.
4. Take out the magnetron very carefully.
5. Remove screws from the back panel.
6. Take out the fan motor.
7. Remove the oven lamp by pulling out from hole of
air cover.
NOTE 1
: When removing the magnetron, make
sure that its antenna does not hit any
adjacent parts, or it may be damaged.
NOTE 2
: When replacing the magnetron, be sure
to remount the magnetron gasket in the
correctposition and make sure the gasket
is in good condition.
1. Discharge the high voltage capacitor.
2. Disconnect all the leads.
3. Remove the mounting bolts.
4. Reconnect the leads correctly and firmly.
PRECAUTION
Servicemen should remove their watches when-
ever working close to or replacing the magnetron.
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH
VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near
these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.
H.V.Trans
H.V.Capacitor
Cover Air
Thermos S/W
Magnetorn
Magnetron
Magnetron
4-1 Replacement of Magnetron, Motor Assembly and Lamp
4-2 Replacement of High Voltage Transformer