background image

The following safety precautions must be taken when installing 
and using your air conditioner.

Safety Precautions

1   

The air conditioner must be plugged into its own specific power source, which must be 

installed in compliance with national wiring, earthing and safety regulations.

Depending on national regulations and your specific installation, you may need to install:

◆ 

A circuit breaker

For further information on electrical requirements, contact a professional electrician.
This device must be installed according to the national electrical rules.

2   

Make sure that the unit is correctly ventilated at all times; 

do NOT place clothing or other materials over it.

4

Do NOT insert anything between the air outlet blades, as the inner fan may be damaged 

and you may be hurt. Particularly, keep children away from the unit.

5

ALWAYS ensure that the power cable is in good condition. 

Make sure that it is not walked on or damaged by items placed on or against it.

If the power cord is damaged in any way, it must be replaced by an approved 
power cord available from the manufacturer or its service agent.

6

Do NOT attempt to repair the unit yourself. If it is damaged in any way, contact:

◆ 

An approved service center

◆ 

The outlet at which the air conditioner was purchased

7

Do NOT place any obstacles in front of the unit.

3

NEVER spill liquids of any kind into the unit. 

Should this happen, unplug the unit and contact your installation specialist.

8

The appliance is not intended for use by young children or infirm person without 
supervision; young children should be supervised to ensure that they do not play with
the appliance.

The manufacturer do not take the responsibility of the accident happened
because the air conditioner is not fixed firmly or installed securely, during
installing or using the product. In case you have difficulty in installation,
you must ask for an installation specialist help. The accident will be hap-
pened in case of installing improperly.

C

C

C

C

A

A

A

A

U

U

U

U

T

T

T

T

II

II

O

O

O

O

N

N

N

N

E-

2

Содержание AZ09A0KE

Страница 1: ...9ZA WH09ZA1A Window type Room Air Conditioner Cool and Heat Acondicionador de aire dom stico sistema de tipo ventana Refrigeraci n y Calefacci n Climatiseur de type Fen tre Refroidissement et Chauffag...

Страница 2: ...on or damaged by items placed on or against it If the power cord is damaged in any way it must be replaced by an approved power cord available from the manufacturer or its service agent 6 Do NOT atte...

Страница 3: ...Heating Your Room 7 Airing Your Room 8 Switching the Air Conditioner Off 8 Adjusting the Air Flow Direction Horizontally 9 Adjusting the Air Flow Direction Vertically 9 RECOMMENDATIONS FOR USE Operati...

Страница 4: ...cated in inside Ventilation lever Power plug The type of power plug may differ depending on the local power supply Air Outlet Air inlet Outside Temperature control dial Operating mode selection dial A...

Страница 5: ...hey will help you take full advantage of the unit s features The booklet is organised as follows The illustration on page 4 shows the air conditioning unit it indicates the location and purpose of the...

Страница 6: ...ng Your Room You must select the Cool mode if you wish to lower the temperature in your room You can also set the fan speed 1 2 To control the direction of the air flow refer to page 9 3 To adjust the...

Страница 7: ...ect the Heat mode if you wish to heat your room to a specific temperature You can also select the fan speed To adjust the temperature turn the temperature control dial towards the left and the red pos...

Страница 8: ...1 Set the operating mode selection dial to the FAN position Both fan settings left and right have the same function Result The air conditioner starts up in Fan mode 2 To control the direction of the...

Страница 9: ...ng switch to the position Result The inner blades swing automatically left and right The blades may stop swinging momentarily when the Deice function is activated see page 10 for further details on th...

Страница 10: ...on When outside temperatures are low and humidity is high frost may form in the unit s condenser when heating with your air conditioner If this happens The unit stops heating The air flow blades stop...

Страница 11: ...from the wall socket Clean the filter and outer surfaces Have not used the air Set the fan going for a few hours to conditioner for a long dry the inside of the air conditioner period of time thoroug...

Страница 12: ...out of the unit PROBLEM The air conditioner does not operate at all The air conditioner does not cool or heat Check that the air conditioner has been switched on if necessary turn the operating mode s...

Страница 13: ...Technical Specifications E 13 ENGLISH Design and specifications are subject to change without notice Power Supply 220 240V 50Hz Model AZ09A1KE WH09ZA WH09ZA1A...

Страница 14: ...arately 1 It is advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstance...

Страница 15: ...and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original co...

Страница 16: ...AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR ESTE APARELHO DE AR CONDICIONADO FABRICADO POR QUESTO CONDIZIONATORE D ARIA PRODOTTO DA...

Отзывы: