background image

E-

7

If you orient the air flow blades downwards and the unit operates
in Cool mode for long periods of time, dew may:

Form on the surface of the blades
Drip from the blades

Adjusting the Air Flow Direction Horizontally

Adjusting the Air Flow Direction Vertically

HSI

L

GN

E

Depending on the position of the unit in your room, you can adjust the

orientation of the inner air flow blades on the right-hand side of the

unit, thus increasing the efficiency of the air conditioner.

1    Set the air flow blade swing switch to the on position.

Result:

The inner blades swing automatically left and right.

2 To stop the blades moving left and right, set the air flow blade swing

switch to the off position.

To stop the blades in a specific position and orient the air flow in
the corresponding direction, simply set the switch to the off
position when the blades are in the desired position.

Again depending on the position of the unit in your room, you can adjust the

orientation of the outer air flow blades on the right-hand side of the unit.
RECOMMENDATION 
When...                           Adjust the blades to face...

Cooling                            Upwards.

Adjust the air flow blades to the desired position, by pushing them
upwards or downwards.

Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges

within which the air conditioner 

can be used in the best condition .

Mode

Indoor Temperature

Outdoor Temperature                             Indoor Humidity

If the air conditioner is used at...

Then...

Higher temperature

Lower temperature

Higher humidity levels

The automatic protection feature may be triggered

and the air conditioner stopped.
A water leakage or some other malfunction may happen

if the heat exchanger freezes.
Water may condense on and drip from the surface of the unit
if it is used for long periods.

Cooling                   21 C to 32 C approx.         21 C to 43 C approx.                            80% or less

Содержание AW09P1HDA

Страница 1: ...cosistemadetipoventana Reirigeraci n ClimatiseurdetypeFen tre Refroidissement OarCondicionadodeWindow Type Refrigerac Condizionatored ariaperambientidafinestra Raffreddamento AW07P1HEA EB AW07P1HBA BB...

Страница 2: ...o its own specific power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufactur...

Страница 3: ...motor can have adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltag...

Страница 4: ...er plug may differ according to the type of local power supply Inner air flow blades right left orientation Outer air flow blades up down orientation Air inlet Outside Ventilation lever Power Cable Ai...

Страница 5: ...Low fan speed HI COOL MED COOL LOW COOL Result The air conditioner starts up in Cool mode The fan starts up at the speed selected You can change modes at any time 2 To adjust the temperature turn the...

Страница 6: ...the operating mode selection dial to the OFF position Result Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the close...

Страница 7: ...h to the off position when the blades are in the desired position Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand...

Страница 8: ...ean the air conditioner Open the grille as much as possible 1 Grasp the lower part of the front grille and the front grille handle then open the grille The open angle of front grille has not to be exc...

Страница 9: ...the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct oper...

Страница 10: ...ical Specifications Design and specifications are subject to change without notice Model Power Supply AA AB BA BB BC BD CA CB DA DB EA EB EC ED 115V 60Hz 220V 230V 60Hz 230 208V 60Hz 200 220V 50Hz 220...

Страница 11: ...plug on the power cord of this appliance Follow national electrical codes or local codes and ordinances If the electric supply provided does not meet the above specifications call a licensed electrici...

Страница 12: ...e circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditione...

Страница 13: ...grille It is secured in the section depending on the model In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner E...

Страница 14: ...f you have any comments or questions regarding a Samsung products contact the SAMSUNG customer care center Country AUSTRALIA Customer Care Center 1300 362 603 Web Site www samsung com au INDIA 3030 82...

Отзывы: