background image

E-

Safety Precautions

The following safety precautions must be taken when using your air conditioner.

WARNING

Risk of electric shock. • Can cause injury or death. • Disconnect all 

remote electric power supplies before servicing, installing or cleaning.  

• This must be done by the manufacturer or its service agent or a similar 

qualified person in order to avoid a hazard.

 

Register your product at www.samsung.com/global/register

D

URING OPERATION

u

Users of this product are cautioned not to attempt repair of this product at their
own discretion. Instead, they are requested to directly contact a designated
service center or the outlet at which the product was purchased.

u

Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch off the unit and contact an authorized service center.

u

Do not insert anything between the air outlet blades because the inner fan may
be damaged and could cause injury. Keep children away from the unit.

u

Do not place any obstacles in front of the unit.

u

Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the breaker used for your air conditioner and contact your installation specialist.

u

Make sure that the unit is correctly ventilated at all times:
Do not place clothing or other materials over it.

u

If the wireless remote control will not be used for a long time, remove the
batteries. (If applicable)

u

When using a wireless remote control, the distance should not be more than 7
meters from the air conditioner. (If applicable)

u

The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.

u

If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.

u

This device must be installed according to the national electrical rules.

u

The appliance must be installation that the plug should be easily accessible
after installation.

u

If the fuse on PC board is broken please change it with the type of T 3.5A 50V.

u

The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.

D

ISPOSING OF THE UNIT

u

Before throwing out the device, it is necessary to pull back the battery cells and
get rid of them safely for recycling reasons.

u

When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectly, refrigerant may blow out and come into contact with your skin,causing
injury. Releasing refrigerant into the atmosphere also damages the environments.

u

Please recycle or dispose of the packaging material for this product in an
environmentally responsible manner.

O

THERS

u

Never store or ship the air conditioner upside down or sideways to avoid damage
to the compressor.

u

The appliance is not intended for use by young children or infirm persons without
supervision: Young children should be supervised to ensure that they do not play
with the appliance.

u

Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy efficiency.

DB98-27204A.indd   2

2007-1-23   9:18:36

Содержание AW07P2 Series

Страница 1: ...AW07P2 Series AW09P2 Series AW12P2 Series Window type Room Air Conditioner Cooling DB98 27204A USER S MANUAL E DB98 27204A indd 15 2007 1 23 9 18 46 ...

Страница 2: ...st be plugged into its own specific power source which must be installed in compliance with national wiring earthing and safety regulations u If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard u This device must be installed according to the national electrical rules u The appliance must be...

Страница 3: ...ommon Problems 10 INSTALLATION 11 Contents CAUTION The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker Before connection this equipment to the power supply system please repor...

Страница 4: ...ow blades up down orientation Air inlet Outside Ventilation lever The design and shape are subject to change according to the model Power plug The type of the power plug may differ according to the type of local power supply Power Cable Operating mode selection dial Temperature control dial Air flow blade swing switch Fan speed switch DB98 27204A indd 4 2007 1 23 9 18 37 ...

Страница 5: ...e air conditioner starts operating 2 To adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18 C and 29 C inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected temperature 3 Press the Fan Speed mode selector to the High or Low position Result The Fan speed is adjusted DB98 27204A indd 5 200...

Страница 6: ...n Result The air simply circulates inside the room 2 To switch the unit on simply turn the Timer dial to Continue position Result The air conditioner starts operating 3 To airing your room only turn the temperature control dial to 1 position Result The air conditioner runs in fan mode 4 Press the Fan Speed mode selector to the High or Low position Result The Fan speed is adjusted Switching the Air...

Страница 7: ...en the operating time reaches zero Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the right hand side of the unit thus increasing the efficiency of the air conditioner 1 Set the air flow blade swing switch to the on position Result The inner blades swing automatically left and right 2 T...

Страница 8: ...Drip from the blades Temperature and Humidity Ranges Mode IndoorTemperature OutdoorTemperature Indoor Humidity Cooling 21 C to 32 C approx 21 C to 43 C approx 80 or less The following table indicates the temperature and humidity ranges within which the air conditioner can be used in the best condition If the air conditioner is used at Then Higher temperatures The automatic protection feature may b...

Страница 9: ...e order of disassembly 2 Pull the air filter to the right side 3 Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished insert the air filter back into its original position 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products If you Then Will not be using the a...

Страница 10: ... temperature may be too low Dust may be blocking the air filter refer to page 8 cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit The air flow direction does not change when you set the air flow blade swing switch to the on position Check that the air conditioner has been switched on if necessary turn the operating mode selection dial refer to page...

Страница 11: ...prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operat...

Страница 12: ...E 12 Rear Rubber cap Screws 2EA Gasket Drain Tube Installation Cont Installation of the Drain Tube Fix the drain tube as shown in the figure DB98 27204A indd 12 2007 1 23 9 18 44 ...

Страница 13: ...E 13 Memo DB98 27204A indd 13 2007 1 23 9 18 44 ...

Страница 14: ...DB98 27204A indd 14 2007 1 23 9 18 45 ...

Отзывы: