background image

Power Failure

Temperature and Humidity Ranges

E-

10

If the air conditioner is used at...

Then...

Higher temperature 

The automatic protection feature may be triggered 

and the air conditioner stopped.

Lower temperature  

A water leakage or some other malfunction may happen 
if the heat exchanger freezes.

Higher humidity levels

Water may condense on and drip from the surface of the unit 
if it is used for long periods.

The following table indicates the temperature and humidity ranges
within which the air conditioner can be used.

Mode

Indoor
Temperature

Outdoor
Temperature

Indoor Humidity

Cooling

70°F to 90°F approx.

70°F to 110°F approx.

80% or less

If a power failure occurs, set the SELECTOR to OFF. When the power
comes back on, wait five minutes before turning the unit back on.

Содержание AW0750/AW0810

Страница 1: ...OWNER S INSTRUCTIONS AW0750 AW0810 AW1010 AW1210 AW1800 AW1810 WINDOW TYPE ROOM AIR CONDITIONER Cool E DB68 00964A 3 S...

Страница 2: ...children away from the unit 7 Do NOT place any obstacles in front of the unit 8 Users of this product are cautioned not to attempt repairs Instead they are requested to directly contact a designated...

Страница 3: ...om 6 Ventilating Your Room 7 Switching the Air Conditioner Off 8 Selecting Energy Saving Mode 8 Adjusting the Air Flow Direction Horizontally 9 Adjusting the Air Flow Direction Vertically 9 RECOMMENDA...

Страница 4: ...ly Selector Thermostat control Energy saver switch Selector Thermostat control Energy saver switch Except AW1800 Inner air flow blades right left orientation The design and shape are subject to change...

Страница 5: ...m air conditioner which should be installed following your Owner s Instructions Your Owner s Instructions contain much valuable information on using your air conditioner Please take the time to read t...

Страница 6: ...tarts up in cool mode N N N No o o ot t t te e e e You can change modes at any time Turn the THERMOSTAT control to the desired position You must select the COOL mode if you wish to adjust the Cooling...

Страница 7: ...n turns rapidly LOW FAN The fan turns slowly You can change modes at any time 2 To control the direction of the air flow refer to page 9 3 If you wish to discharge stale air push the ventilation lever...

Страница 8: ...the energy saving feature set the Energy Saver switch to the OFF position Result The fan runs at all times while the compressor cycles on and off 2 To select the energy saving mode set the Energy Sav...

Страница 9: ...adjusted to direct the air flow to the left right or straight thus increasing the efficiency of the air conditioner The side by side air direction louvers are controlled by a lever They regulate air...

Страница 10: ...freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods The following table indicates the temperature and humidity ranges within whic...

Страница 11: ...grille lift it up as much as possible then pull down to release it N N N No o o ot t t te e e e Front grille Grille groove Body guide Front grille Be sure to clean the air filter periodically to main...

Страница 12: ...there is any obstacle adversely affecting the flow of the air inside and outside the room Remove the obstacle or change the position of the air conditioner Check to see whether the air filter is clog...

Страница 13: ...ations Model Power Supply AW0750 AW0810 AW1010 AW1210 115V 60Hz AW1800 AW1810 230V 208V 60Hz Design and specifications are subject to change without notice E 13 Cooling Capacity BTU h 7800 8000 10000...

Страница 14: ...ents routine maintenance and cleaning consumable items such as filters use of non SAMSUNG or unauthorized parts supplies accessories or equipment which damage this product or result in service problem...

Отзывы: