Installation of the Drain Tube

Fix the drain tube as shown in the figure.

Installation of the Drain Pan

The procedure for installing the drain pan should be determined by the
condition of the installing area. 

◆ 

In the case of an area where the drain pan can not be directly 

installed on the rear side of the unit after installing the air conditioner.
Example: High storage

◆ 

In the case of an area where the drain pan can be directly installed 
on the rear side of the unit after installing the air conditioner.

Remove two screws on the lower, right and left sides of the unit.

4

Open the front grille ; refer to page 15 or 16.

1

Remove the screw located at the lower section of the front grille.
It is secured in the              section depending on the model.

2

Remove the chassis from the cabinet.

5

Remove the rubber cap inserted into the basepan.

6

Fix the drain pan as shown in the figure, and then connect the drain hose.
(You can use any commercially-available drain hose.)

7

Install the cabinet at the specified area after installing the drain pan,
and then re-assemble it in the original condition.

8

Follow steps 6 and 7 only

1

Remove the front panel.

3-1 Press both sides of the cabinet in the direction of the arrow

as shown in the figure.

3-2 Pull the lower part of the front panel slightly forward.

(below three inches)

3-3 Lift the front panel upward.

3

Applying excessive force to remove the front panel 
may cause damage to the tab ; be sure not to use 
excessive force.

E-

21

ENGLISH

Rubber cap

Screws(2EA)

Gasket

Rear

Drain Tube

Front panel

Screw

Rubber cap

Drain Hose

Bottom-Side View with
Drain Pan and Hose in Place

Rear

Drain Pan

Screw

Secure the front panel to the case by replacing the screw removed in
step 2. If a screw not removed in step 2, secure the panel with a
supplied screw.

In some region, drain tube and drain pan may not be supplied.  
Please contact the sales agent.

Содержание AW06FANAA

Страница 1: ...A AB AC AW09FANAA BA CA DA EA EB AW10FADAA BA CA AW12FADAA BA CA DA EA EB EC AWT12FADBA BB BC EA EB AW14FAMAA AB BA CA DA EA AW18FAMBA BB BC BD DA EA EB AW18FAMCA CB CC AWT18FAMBA BB BC DA EA EB AWT19...

Страница 2: ...en away from the unit 5 ALWAYS ensure that the power cable is in good condition If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qual...

Страница 3: ...5 Solving Common Problems 17 Technical Specifications 18 INSTALLATION 19 E 3 ENGLISH C C C CA A A AU U U UT T T TI I I IO O O ON N N N The maximum permissible system impedance at the power junction bo...

Страница 4: ...ing on the model Power plug Power cable Power cable connection should be committed to an installation engineer Blue Brown Yellow Green Main Power Earth Fan speed indicators LOW MED HIGH Temperature Ti...

Страница 5: ...info Remote Control Buttons Temperature adjustment buttons Fan speed adjustment buttons ON OFF button E 5 ENGLISH Timer setting button Sleep timer setting button Operating mode selection buttons Energ...

Страница 6: ...our air conditioners The booklet is organized as follows The following figures are shown on pages 4 and 5 Air conditioning unit main parts buttons and display Remote control buttons They will help you...

Страница 7: ...ompletely discharged after 12 months even if they have not actually been used 1 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it 2 I...

Страница 8: ...change modes at any time 3 To adjust the temperature press the or button on the remote control one or more times until the required temperature is displayed To adjust the temperature press the or but...

Страница 9: ...sed The unit beeps twice 3 If the FAN indicator is not lit up on the unit Press the button on the remote control or Press the MODE button on the unit one or more times until the FAN indicator lights u...

Страница 10: ...tton on the remote control To stop the blades in a specific position and orient the air flow in the corresponding direction simply press the or on the unit button on the remote control when the blades...

Страница 11: ...lusive Result The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time The air conditioner switches on automatically when the operating time reaches zero Yo...

Страница 12: ...ntrol or Timer on the unit one or more times Possible times are between 1 hour and 24 hour inclusive Result The remaining time is displayed and decreased by 1 hour automatically to indicate the remain...

Страница 13: ...el for about 15 seconds and the will be displayed The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time The air conditioner will be controlled as illustr...

Страница 14: ...u select the Sleep Timer in the Energy Saving mode the Energy Saving will be cancelled and the air conditioner will start up in the Sleep Timer mode If you wish to save energy when using your air cond...

Страница 15: ...s original position 4 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products 5 The removal of the fro...

Страница 16: ...the air conditioner After opening the front grille lift it up as much as possible then pull down to release it Be sure to clean the air filter periodically to maintain the air conditioner in the best...

Страница 17: ...control batteries if necessary Check that you are close enough to the unit seven metres yards or less No beep is heard when you press On Off on the remote control Check that you are pointing the remo...

Страница 18: ...nuals info Technical Specifications E 18 Design and specifications are subject to change without notice Model AA AB AC BA BB BC BD CA CB CC CD DA DB EA EB EC Power Supply 115V 60Hz 220V 230V 60Hz 230...

Страница 19: ...any circumstances cut or remove the third grounding prong from the power cord We recommend that you do not use an extension cord or an adapter plug with this appliance Do not change the plug on the po...

Страница 20: ...urability for operation of the air conditioner and for prevention of any vibration or noise If it is weak reinforcement work should be performed separately 1 It is advisable to install the air conditi...

Страница 21: ...ted into the basepan 6 Fix the drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the specified area after inst...

Страница 22: ...rea THIS AIR CONDITIONER IS MANUFACTURED BY ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQU PAR ESTE APARELHO DE AR CONDICIONADO FABRICADO POR QUESTO CONDIZIONATORE D ARIA...

Отзывы: