3-2
Samsung Electronics
3-2 Controls and Components
3-2-1 Thermostat
3-2-2 Operating Switch
HI
COOL
HI
FAN
LOW
FAN
LOW
COOL
OFF
6
COOLEST
2
4
8
10
12
Timer indicator
Temperature indicator
1) Off :
When room temperature is lowered by using the air conditioner, the gas within the thermostat
will contract and cause a break in the electrical contact. The compressor will stop.
After the compressor stops, the room temperature will rise.
2) On :
As the room temperature increases to a selected level, the gas of the thermostat expands
causing electrical contact, which provides source of electric power to the compressor.
the room temperature will fall and the cycle will repeat.
3) Control Operation :
By turning control knob clockwise(toward higher numbers), the temperature will be cooler.
By turning the control knob counterclockwise(toward lower numbers), the temperature will be warmer.
Level 1 : Cool air will be supplied above 30~35¡C
Cool air will be ceased below 28~32.5¡C
Level 12 : Cool air will be supplied above 11~17¡C
Cool air will be ceased below 7~13¡C
¥ Slowly turn the Fan Selector Switch in the following order : to LOW FAN, HIGH FAN, LOW COOL, HIGH COOL.
¥ OFF : All functions will be off.
¥ LOW FAN : The circulation of air is low.
¥ HIGH FAN : The circulation of air is maximum.
¥ LOW COOL : Circulation, cooling, and humidity removal are low(all simultaneousy operated).
¥ HIGH COOL : Circulation, cooling, and humidity removal are maximum(all simultaneously operated).
AW-05B0LA(AW0519)-1 11/27/98 2:05 PM Page 3-2