background image

Safety Precautions

If the power supply cord of this air conditioner is damaged,  
it must be replaced by the manufacturer or its authorized 
service personnel only in order to avoid a safety hazard.

WARNING

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized
service personnel for repairs.

When moving, consult authorized service personnel for disconnection
and installation of the unit.

Do not become over-exposed to cold air by staying in the direct path of
the airflow of the air conditioner for extended periods of time.

Do not insert fingers or objects into the outlet port or intake grilles.

Do not start and stop air conditioner operation by disconnecting the
power supply cord and so on.

Take care not to damage the power supply cord.

In the event of a malfunction (burning smell, etc.), immediately stop 
operation, turn off the electrical breaker, and consult authorized 
service personnel.

DANGER

Provide occasional ventilation during use.

Do not direct air flow at fireplaces or heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of air conditioners.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Do not pull power supply cord.

Turn off power source when not using the unit for extended periods.

Check the condition of the installation stand for damage.

Do not place animals or plants in the direct path of the air flow.

Do not drink the water drained from the air conditioner.

Do not use in applications involving the storage of foods, plants or 
animals, precision equipment, or art works.

Do not apply any heavy pressure to radiator fins.

Operate only with air filters installed.

Do not block or cover the intake grille and outlet port.

Ensure that any electronic equipment is at least one metre away from
either the indoor or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating 
apparatus.

When installing the indoor and outdoor unit, take precautions to prevent
access to infants.

Do not use inflammable gases near the air conditioner.

Max input power & current is measured according to IEO standard and
input power & current is measured according to ISO standard.

CAUTION

E-

2

Содержание AVMPC060EA0MID

Страница 1: ...OWNER S INSTRUCTIONS System Air Conditioner AVMPH060EA0 AVMPH070EA0 AVMPH082EA0 Heat pump AVMPC060EA0 AVMPC070EA0 AVMPC082EA0 Cooling only E DB98 07286A 1...

Страница 2: ...Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditione...

Страница 3: ...s Remote Controller Buttons and Display 6 Centralized Controller 7 Using the Control Panel on the Indoor Unit 8 RECOMMENDATIONS FOR USE Operating Recommendations 9 Cleaning Your Air Conditioner 10 Tem...

Страница 4: ...peed adjustment button Mode Selection button On Off button Automatic shutter Air filter Remote control holder Indoor Unit E 4 Control Panel You can operate the air conditioner with the control panel w...

Страница 5: ...t Connection valve TYPE D Outdoor Unit Air outlet Connection valve TYPE E Outdoor Unit E 5 If the heat exchanger in the outdoor unit gets dusty cooling efficiency may fall So clean the heat exchanger...

Страница 6: ...t buttons Temperature setting Fan speed Air flow direction On Timer setting Off Timer setting Clean mode Air cleaning button Battery discharge indicator E 6 The wireless remote controller is an option...

Страница 7: ...on the wall To use the centralized controller refer to an appropriate manual Operating lamp All On button All Off button On Off indicators On Off buttons Index Operating lamp comes on when at least on...

Страница 8: ...urn each time you press the button Result If you finish setting the temperature the current temperature indicates on the control panel 3 To adjust your desired temperature press the buttons once or mo...

Страница 9: ...n the outdoor unit at HEAT mode If this happens The heating operation stops The defrost mode will be triggered automatically for about ten minutes and the defrost indicator lights up No intervention i...

Страница 10: ...ave switched off the breaker for the unit IMPORTANT Remove all dust on the air filter with a vacuum cleaner or brush 2 When you have finished insert the air filter into the original position and close...

Страница 11: ...detergent in tepid water then put the Electric dust collector in the water for 30 minutes 2 Dry the electric dust collector in the shade then insert the collector into the original position close the...

Страница 12: ...ezes Low temperature Water may condense on and drip from the surface of the indoor unit if it is used for a long periods High humidity levels If the heating operation is used at below 0 C outdoor temp...

Страница 13: ...If there is a strong light around the air conditioner a three wavelength light a neon sign etc for example the air conditioner may not be operated with a remote controller If this happens use the remo...

Страница 14: ...Technical Specifications E 14 Power Supply Model 1 220 240V 50Hz AVMPH060EA0 AVMPH070EA0 AVMPH082EA0 AVMPC060EA0 AVMPC070EA0 AVMPC082EA0...

Страница 15: ...Memo E 15...

Страница 16: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY Printed in Korea...

Отзывы: