Y
N
Y
Y
Y
N
N
N
N
Y
N
Y
N
Y
Samsung Electronics
5-2
5-2 Fault Diagnosis by Symptom
5-2-1 No Power (completely dead)-Initial diagnosis
1 ) Checklist :
(1) Is input voltage normal? (198-264V~)
(2) Is AC power linked corre c t l y ?
(3) A re connections between primary side, secondary side of the power transformer
and PCB good.
(4) Is output voltage of DC regulator IC KA7812(IC01) normal? (11 . 5 V D C - 1 2 . 5 V D C )
(5) Is output voltage of DC regulator IC KA7805(IC02) normal? (4.5VDC-5.5VDC)
2 )
Troubleshooting pro c e d u re
Remove power cord and plug in again in approx. 5 seconds.
Is operating lamp lights on for
three minutes, and then goes off?
Normal
Replace the fuse (250V, 3.15A)
Replace the trans.
Replace the IC01.
Replace the IC02.
Replace the assembly display PCB
Harness check and replace
Check whether the fuse is normal? (F701)
Check whether the output voltage of the trans
is normal? (AC 15V±3V)
Check whether the DC 12V is normal?
(DC12±0.5V between "G" and "O" of the IC01)
Is the harness properly connected(CN93, CN94)?
Check whether the display PCB is normal?
(Check the DC 5V, DC12V, wire, etc.)
Replace the assembly main PCB.
Check whether the DC 5V is normal?
(DC 5V°æ0.5V between "G" and "O" of the IC02)
Содержание ASH180UE
Страница 2: ...Samsung Electronics Co Ltd APR 1998 Printed in Korea Code No DB81 10154A...
Страница 4: ...1 2 Samsung Electronics MEMO...
Страница 33: ...Samsung Electronics 5 11 MEMO...
Страница 34: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Страница 40: ...6 7 Samsung Electronics MEMO...
Страница 43: ...Samsung Electronics 7 3 MEMO...
Страница 48: ...8 5 Samsung Electronics MEMO...
Страница 49: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Страница 51: ...Samsung Electronics MEMO...
Страница 52: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Страница 53: ...Samsung Electronics 10 2 10 2 Remote Control...