background image

Setting the Sleep Timer

The Sleep Timer can be used when you are cooling your room to
switch the air conditioner off automatically after a period of 6 hours.

N

N

N

N

o

o

o

o

tt

tt

e

e

e

e

If you wish to switch the unit off at a specific time, refer to
page 19.

1

Make sure that you have selected the COOL mode.

2

Press the          button.

Result:

The indoor unit beeps. 

The air conditioner will be controlled as indicated in the  

illustrations below.

Cooling

The desired temperature is
increased by 1°C every hour.
When it has been increased
by 2°C (after 2 hours), the
temperature is maintained for
four hours.

To Cancel the Sleep Timer

If you no longer wish to use the Sleep Timer that you have set, you
can cancel it at any time.

Press the           button.

Result:

The indoor unit beeps. 

The      is no longer displayed.

The air conditioner operates normally.

E-

20

Содержание AS09P8GD/XSV

Страница 1: ...DB98 21804A AS09P8GD AS09P8GE AS12PHGD Indoor unit US09P8GD US09P8GE US12PHGD AS12PHGE Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER Cool OWNER S INSTRUCTIONS E US12PHGE...

Страница 2: ...than 7 meters from the air conditioner If applicable WARNING DURING OPERATION Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not int...

Страница 3: ...ring Your Room 13 Selecting Energy Saving Mode 14 Generating Anion 15 Adjusting the Air Flow Direction Vertically 16 Adjusting the Air Flow Direction Horizontally 17 PROGRAMMING YOUR AIR CONDITIONER S...

Страница 4: ...the temperature on the display N N N No o o ot t t te e e e Indoor Unit Air filter under the grille Air flow blades outlet Remote Control Sensor On Off switch Timer indicator Fan speed setting Sleep T...

Страница 5: ...E 5 Outdoor Unit Air Inlet Rear Air Outlet Air Outlet Connection Valve Connection Valve Outdoor Unit US09P8GD US09P8GE US12PHGD US12PHGE Air Inlet Rear...

Страница 6: ...n button Sleep button Energy saving button Swing button Timer Set Cancel button Temperature adjustment buttons Temperature setting Air flow direction Turbo mode Sleep mode On Off button Mode selection...

Страница 7: ...ou take full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They...

Страница 8: ...battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries togethe...

Страница 9: ...s up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps The air conditioner is fitted with a protection mechanism to prevent the unit from being damag...

Страница 10: ...time N N N No o o ot t t te e e e To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusive Re...

Страница 11: ...up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The air c...

Страница 12: ...er three minutes 2 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press t...

Страница 13: ...of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mode The te...

Страница 14: ...cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to pages 16 and 17 5 To select the fan speed press the button one or more times until th...

Страница 15: ...ir conditioner generates anion The indoor unit beeps 2 If you wish to stop the Anion function press the button again Result The air conditioner is reset automatically to the previous mode temperature...

Страница 16: ...uired Result The outer blade is adjusted vertically RECOMMENDATION When Adjust the blade to face Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is o...

Страница 17: ...ere are two sets of inner air flow blades Just as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally 1 Adjust each set of inner blades to the required po...

Страница 18: ...nclusive 1 Press the Set Cancel button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappe...

Страница 19: ...on to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote contr...

Страница 20: ...s the button Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been...

Страница 21: ...t you should follow when using your air conditioner Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns t...

Страница 22: ...ty levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods E 22 Operating Your Air Conditioner Without the Remote Control Your air conditioner can be o...

Страница 23: ...re may be too low Dust may be blocking the air filter guard refer to page 24 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set...

Страница 24: ...ve finished insert the top part of the filters into their slot and push down on the bottom edge until they click into place 7 Clean the front grille with a damp cloth and mild detergent do NOT use ben...

Страница 25: ...and left sides of the grille To remove minute dust particles and odors Deodorizing Bio Green and Titanium filters are installed in the air conditioner You should clean the filters every 3 months 5 Clo...

Страница 26: ...E 26 Memo...

Страница 27: ...E 27 Memo...

Страница 28: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY...

Отзывы: