29
Samsung Electronics
1.
AUTO MODE : In this mode, operation mode(COOL,
HEAT) is selected automatically by the difference
between the setting and room temperature.
√
√
In case of Heat pump model.
√
√
Cooling or heating operation is selected based on
difference of Ts and Tr. Cooling and heating operation
is automatically interchanged during operation.
√
√
In case of Cooling only model.
Ts : Setting temperature. Tr : Room temperature.
2.
COOL MODE : The unit operates according to the
difference between the setting and room temperature.
(Set temperature range is 16˚C ~ 30˚C)
3.
HEAT MODE(In case of Heat pump model) :
The unit operates according to the difference between the
setting and room temperature.(16°C~30°C)
*Prevention against cold wind : In order to prevent the
cool air from flowing out at the heat mode, the indoor fan
does not operate or operates very slowly in the following
cases. At this time, the indoor heat exchanger will be
preheated.
- For 3~5 minutes after the initial operation
- For de-icing operation
- The operation of the indoor fan in accordance with the
temperature of the indoor heat exchanger
*High temperature release function : It is a function to
detect an outdoor overload by the sensing of the indoor
heat exchanger and to turn the outdoor fan or the
compressor ON or OFF for safety.
*De-ice : De-icing operation is controlled by the indoor
unit's heat exchanger temperature and accumulating
time of compressor's operation.
De-ice ends by sensing of the processing time of the
de-ice condition.
4.
DRY MODE : Has 4 states, each determined by room
temperature.
The unit operates in DRY mode.
*Compressor ON/OFF time is controlled compulsorily
(can not set up the fan speed, always breeze).
*Protective function : Low temperature release.
(Prevention against freezing)
5.
TURBO MODE : This mode is available in AUTO, COOL,
HEAT, DRY, FAN MODE.
When this button is pressed, the air conditioner is
operated in "powerful" state for 30 minutes regardless of
the setting temperature and room temperature.
When this button is pressed again, or when the operating
time reaches 30 minutes, turbo operation mode is
canceled and the air conditioner is returned to the
previous mode.
*But, if you press the TURBO button in DRY or FAN
mode that is changed with AUTO mode automatically.
6.
SLEEP MODE : Sleep mode is available only in COOL or
HEAT mode.
The operation will stop after 6 hours.
*In COOL mode : The setting temperature is automatically
raised by 1°C each 1hour When the temperature has
been raised by total of 2°C, that temperature is
maintained for the next 4 hours.
*In HEAT mode : The setting temperature is automatically
dropped by 1°C each 1 hour.
When the temperature has been dropped by total of
2°C, that temperature is maintained for the next 4 hours.
7.
FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending on the
difference between setting and the room temperature.
8.
COMPULSORY OPERATION :
For operating the air conditioner without the remote
control.
*The operating is the same function as AUTO MODE with
the remote control.
below 28˚C
28˚C~below 34˚C
34˚C~below 40˚C
above 40˚C
The temperature of
indoor heat exchanger
Indoor fan speed
off
LL Speed
L Speed
Setting Speed
Operation Type
Room Temp.
Cool Operation
Tr
≥
Ts+1.0°C
Compressor ON
Tr
≤
Ts
Compressor OFF
6-2 Details of proper operation
DB98_20801A(1)_1 12/24/04 10:46 AM Page 29
Содержание AS09HPA
Страница 62: ...MEMO 61 Samsung Electronics ...
Страница 69: ...Samsung Electronics 68 11 PCB Diagram 11 1 ASS Y MAIN PCB DB93 02482A TOP ...
Страница 70: ...69 Samsung Electronics PCB Diagram BOTTOM ...
Страница 74: ...73 Samsung Electronics 11 2 ASS Y MELODY PCB DB93 02809A TOP BOTTOM ...
Страница 81: ...MEMO Samsung Electronics 80 ...