background image

Adjusting the Air Flow Direction Vertically

Adjusting the Air Flow Direction Horizontally

E-

15

ENGLISH

Depending on the position of the indoor unit on the wall of your
room, you can adjust the position of the outer air flow blade on the
bottom of the unit, thus increasing the efficiency of the air
conditioner.

1

Press the           button one or more times as required.

Result:

The outer blade is adjusted vertically.

RECOMMENDATION

When...

Adjust the blade to face...

Cooling

Upwards.

2

If you want the blade to move up and down automatically when the air
conditioner is operating, press the           button.

Result:

The blade move up and down, around the base position set.

3

To stop the blade moving up and down, press the

button again.

N

N

N

N

o

o

o

o

tt

tt

e

e

e

e

If you switch the air conditioner... Then the blade is...

Off

Closed completely.

On again

Set to the initial position powered.

1

Adjust each set of inner blades to the required position, by pushing or
pulling them sideways.

There are two sets of inner air flow blades. Just as the outer air flow
blade can be adjusted vertically, the inner blades can be adjusted
horizontally.

Содержание AS07S8GB

Страница 1: ...er ambienti ad unit Separate Raffreddamento Aparelho de ar condicionado tipo Split Refrigera o Geteilte raumklimaanlage K hlen IAIPOYMENO K IMATI TIKO MATIOY ESPA OL FRAN AIS ITALIANO PORTUGU S DEUTSC...

Страница 2: ...orized service personnel DANGER Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang...

Страница 3: ...12 Airing Your Room 13 Selecting Energy Saving Mode 14 Adjusting the Air Flow Direction Vertically 15 Adjusting the Air Flow Direction Horizontally 15 PROGRAMMING YOUR AIR CONDITIONER Setting the On T...

Страница 4: ...ubject to change according to the model Indoor Unit Air filter under the grille Air flow blades outlet Air Inlet Remote Control Sensor On Off switch TURBO indicator RED Operation indicator GREEN Energ...

Страница 5: ...B US07S8GE US09S8GB US09S8GE Air Inlet Rear Air Outlet Connection Valve Outdoor Unit US07SBGE US09SBGE US12SBGE Air Inlet Rear Air Outlet Connection Valve inside Outdoor Unit US12SGGB US12SGGE US14SGG...

Страница 6: ...N Turbo Sleep mode selection button Swing button On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Sleep mo...

Страница 7: ...ake full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will...

Страница 8: ...battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries togethe...

Страница 9: ...odes at any time If necessary press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The ind...

Страница 10: ...any time N N N No o o ot t t te e e e To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusiv...

Страница 11: ...air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The air condition...

Страница 12: ...after three minutes 2 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you pre...

Страница 13: ...the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mod...

Страница 14: ...C cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to page 15 5 To select the fan speed press the button one or more times until the req...

Страница 15: ...Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is operating press the button Result The blade move up and down around the base position set 3 To st...

Страница 16: ...ton to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappear after 10 seconds The air conditi...

Страница 17: ...inking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting 2 If yo...

Страница 18: ...s until appears on the remote control Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C ev...

Страница 19: ...tioner can be used If the air conditioner is used at Then High temperatures The automatic protection feature may be triggered and the air conditioner stopped Mode Outdoor Temperature Indoor Temperatur...

Страница 20: ...ndoor unit Result The OPERATION indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature Room Temperature Operating...

Страница 21: ...y be too low Dust may be blocking the air filter guard refer to page 22 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set to C...

Страница 22: ...r air conditioner ensure that you have switched off the breaker used for the unit 1 Slide the lower front grille down 2 Open the upper front grille by pulling right and left sides of the grille 3 Lift...

Страница 23: ...Specifications E 23 ENGLISH Model Indoor unit AS07S8GE AS07SBGE AS09S8GE AS09SBGE AS12SBGE AS12SGGE AS18S0GE AST24S6GE 220 240V 50Hz AS07S8GB AS09S8GB AS12SGGB AS14SGGB AS18S0GB AS24S6GB 220V 60Hz Pow...

Страница 24: ...URED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO FABRICADO POR DIESE KLIMAANLAGE IST FABR...

Отзывы: