10-2-12 Compressor wire missing error/rotation error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1
LED2
LED3
E467
Compressor wire missing
errorr/rotation error
◎
{
◎
Outdoor display
O
{
O
Compressor wire missing error/rotation error
O
LED ON
◎
LED BLINKING
{
LED OFF
1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after power off.
Exchange the compressor
Is the restart error occurred again?
Is the connection of
compressor wire is normal?
(PBA and Compressor)
Is the restart error occurred again?
Is the compressor body and
interphase resistance insulated?
NO
NO
NO
NO
Terminate the service
Connect the comp wire normally
Terminate the service
Exchange the Outdoor PBA
YES
YES
YES
YES