Sa
m
sung Electronics
10-35
10-2-29 EEV or Valve Close error-Self diagnosis
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1
LED2
LED3
E422
EEV or Valve Close error-Self diagnosis
Outdoor display
EEV or Valve Close error-Self diagnosis
LED ON
LED BLINKING
LED OFF
1. Checklist :
1) Is the position ofi ndoor Eva_in sensor nor
m
al?
2) Check the pipe crack
3) Check the EEV valve connection("A") in Outdoor unit
4) Check the refrigerant was charged
2. Troubleshooting procedure
Restart after power off
Check the EEV valve operation.
E
x
change the Indoor PBA
E
x
change the Outdoor PBA
Is the position ofi ndoor eva_in sensor nor
m
al?
Is the gas leak error appeared again?
Is the EEV valve connection nor
m
al?
Is the EEV valve is operation?
Check the sound of EEV valve after power on.
Is the pressure of refrigerant nor
m
al?
NO
NO
NO
NO
NO
Connect the EEV valve.
Ter
m
inate the service.
Indoor sensor take the nor
m
al position
Change the EEV valve.
Check the pipe crack.
Fill up the refrigerant.
YES
after 20
m
inutes later
YES
YES
YES
YES
MODEL
"A"
DB92-02866A/2867A CN701
Содержание AR12HSSDPWKNEE
Страница 9: ...DB93 15169G DB68 04937A MANUAL USERS DB68 04419A...
Страница 12: ...Samsung Electronics 3 3 Outdoor LED Display Error and Check Method...
Страница 17: ...3 12...
Страница 18: ...Download connector 10pin 3 13...
Страница 29: ...4 8 Samsung El ectronics 2 2...
Страница 50: ...Samsung Electronics 7 1 7 Wiring Diagram 7 1 Indoor Unit...
Страница 51: ...7 2 Samsung Electronics 7 2 Outdoor Unit...
Страница 96: ...11 2 Samsung Electronics 11 2 Outdoor unit...