10-
Is the sensor resistance value #1-#2
10kohm 3% at the room
temperature
of 25
Detach the assembled sensor from the PBA sensor
connector and measure the sensor resistance with
ohmmeter(tester)
Sensor Replace
Sensor resistance value : 20 - 12.09kohm
30 - 8.31kohm
35 - 6.94kohm
40 - 5.83kohm
Below 0.5V or Over 4.5V?
Connect the sensor to PBA connector (4piin)
supply power and measure the voltage of #1-#2 in
the connector
Exchange the indoor PBA
NO
YES
NO
YES
Micom error or connector check
Exchange the indoor PBA
YES