3-1 Test Mode
u
How to Approach Test Mode
You can approach the test mode by pressing the on/off
switch of indoor unit for 5 seconds.
u
Test mode operation option
After installing the air conditioner, check whether each subordinate is normally operated or not by
operating the test mode.
•
When an Error occurs, display the Error Mode.
•
Operation Mode : Cool mode. operate the cool mode by operating the compressor by force
without the compressor ON/OFF according to the set temperature/indoor temperature. (Do not
follow the antifreeze control)
•
Up-down louver : Up-down swing mode
•
Indoor Fan : Turbo
Note
•
Because the heat mode operate the cool mode by force not related to the set temperature
/ indoor temperature, check whether each subordinate is operated normally or not after
completing installation and must turn off the power of the air conditioner.