10-32
Samsung Electronics
10-2-26 AC zero cross signal error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1
LED2
LED3
E472
AC zero cross signal error
Outdoor display
AC zero cross signal error
LED ON
LED BLINKING
LED OFF
1. Checklist :
1) Check the power condition at customer's house (Is there any power noise?)
2) Have been there power failure?
2. Troubleshooting procedure
Restart after power off
Exchange the Outdoor PBA
Is the AC line zero cross signal error appeared again?
NO
Terminate the service
YES
MODEL
Error display
DB92-02866A/2867A O