10-22
Samsung Electronics
10-2-19 Heatsink sensor error/Heatsink over heat
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1
LED2
LED3
◎
{
◎
E474
Heatsink sensor error
E500
Heatsink Over Temperature Error
Outdoor display
◎
◎
O
Heatsink sensor error
◎
O
{
Heatsink Over Temperature Error
O
LED ON
◎
LED BLINKING
{
LED OFF
1. Checklist :
1) Are there screws assembly in PBA-heatsink?
2) Is the gap PBA-heatsink
3) Is the fan operation normal?
4) Is the cover assembly in control-bo
x
normal?
2. Troubleshooting procedure
Restart after power off.
E
x
change the Outdoor PBA
Are there screws in PBA-heatsink?
(4 screws)
Is the fan operation normal?
NO
NO
Fastening the screw
Check the fan connection
Change the Fan motor
YES
YES
Содержание AR09HSFSHWKNCV
Страница 33: ... 4 2 Outdoor Unit 3 Detach the Cabinet Upper li e the picture ...
Страница 35: ...8 3 9 ...
Страница 36: ...4 2 4 ...
Страница 82: ...SamsungEle ctr onic s 7 1 7 Wiring Diagram 7 1 Indoor Unit ...
Страница 83: ...7 2 Samsung Electronics 7 2 Outdoor Unit ...
Страница 87: ...8 4 Samsung Electronics Outdoor PCB OUTDOOR MAIN PBA 24K ...
Страница 88: ...Samsung Electronics 8 5 Outdoor PCB OUTDOOR INVERTER PBA 24K ...
Страница 89: ...8 6 Samsung Electronics Outdoor PCB OUTDOOR EMI PBA 24K ...
Страница 90: ...Samsung Electronics 8 7 Outdoor PCB OUTDOOR SUB PBA 24K ...
Страница 178: ... 4 2 Outdoor Unit 3 Detach the Cabinet Upper li e the picture ...
Страница 180: ...8 3 9 ...
Страница 181: ...4 2 4 ...
Страница 182: ...4 2 5 1 1 Release Nut at Fan Boss 2 Release 3 screws st Motor Brac et 3 Detach Motor Wire from the Assy Control Out ...
Страница 206: ...SamsungEle ctr onic s 7 1 7 Wiring Diagram 7 1 Indoor Unit ...
Страница 207: ...7 2 Samsung Electronics 7 2 Outdoor Unit ...