65
9-2-16 When the remote control is not receiving
1. Checklist :
1) Check if the connector was normally assembled.
2) Check the battery in remote control
3) All the lights out and check again : Change electronic typed to a rescent light
4) Put the set in operation and check the voltage of display PBA
5) Replace the display PBA
2. Troubleshooting procedure
NO
NO
NO
YES
YES
YES
NO
If the connector was normally assemble?
Have the battery in remote control?
Insert the battery in remote control.
All the lights out ?
Change electronic typed fluorescent light.
Re-check the connector
Exchange the display PBA
Check the connector to normally assemble.
Содержание AR09AXKAAWKNEU
Страница 38: ...38 6 Wiring Diagram 6 1 IndoorUnit CODE DB68 08680A 01 ...
Страница 39: ...39 6 2 OutdoorUnit CODE DB68 08682A 01 ...
Страница 40: ...40 7 PCB Diagram 7 1 IndoorMain PCB CODE DB92 05042A ...
Страница 41: ...41 7 2 OutdoorMain PCB CODE DB92 04837M ...
Страница 42: ...42 ...
Страница 43: ...43 7 3 DISPLAY PCB ...