2-2
Samsung Electronics
Model
Item
AQV18VBE AQV18VBEX
AQV24VBE AQV24VBEX
Type
Wall-mounted
Performance
Capacity
Cooling
Btu/hr
(Low / Std / Max)
6,600/ 18,000/ 21,000
6,300/ 20,500/ 28,000
Heating
Running Frequency
Cooling
Hz
(Low / Std / Max)
15 / 40 / 46
Heating
15 / 44 / 62
ℓ/h
g
n
i
y
f
i
d
i
m
u
h
e
D
2.5
Air Volume
Cooling
/min
(H/M/L)
10.1/11.7/13.3
Heating
12.7/14.3/15.9
6,600/ 24,000/ 27,000
6,300/ 27,000 / 33,000
15 / 60 / 68
15 / 61 / 85
3.0
10.8/12.4/13.98
12.8/14.4/16.0
Noise
Cooling
dB
(H/L)
8
4
8
4
Heating
48
58
58
48
60
60
SEER
Cooling
(Std)
16
HSPF
Heating
8
z
H
-
V
-
h
p
r
e
w
o
P
1-208/230-60
15.5
7.8
1-208/230-60
Power
Power Consumtion
Cooling
W
(Low / Std / Max)
630 / 1,700 / 1,950
630 / 2,900 / 3,150
Heating
590 / 1,850 / 2,650
590 / 2,900 / 4,000
Operating Current
Cooling
A
(Low / Std / Max)
3.0 / 7.5 / 9.0
Heating
2.8 / 8.2 / 12.0
3.0 / 12.0 / 13.8
2.8 / 13.0 / 18.0
Power Factor
Cooling
%
(Low / Std / Max)
75 / 90 /95
Heating
75/ 90 /95
75 / 90 /95
75/ 90 /95
A
e
z
i
S
r
e
k
a
e
r
B
20
MCA
17.17
MOP
30
Size
Outer Dimension
Width x Height x Depth
inch
mm
41.9x11.7x8.6
Weight (Net)
lb
kg
Drain Hose
D(inch) x L(ft)
Φ0.7 x 1.8
D(mm) x L(mm)
Φ18 x 550
Compressor
Type
Rotary, G8T260FUAEW
Motor
Type
Hermetic
Rated Output
W
2454W
Oil Type
FREOLα68ES-T
A
A
L
R
13.0
Blower
Type
Cross-flow
Propeller
Motor
Type
Resin / Steel, AC
Resin / Steel, DC
Rated Output
W
40
FLA
0.3A 65W
90
0.6A 130W
Piping
Maximum Spec.
Length
ft (m)
98.4(30)
Height
ft (m)
49.2(15)
Refrigerant Pipe
Liquid
OD(inch) x L(ft)
Φ1/4 x 24.6
OD(mm) x L(m)
Φ6.35 x 7.5
98.4(30)
49.2(15)
Φ1/4 x 24.6
Φ6.35 x 7.5
Gas
OD(inch) x L(ft)
Φ1/2 x 24.6
OD(mm) x L(m)
Φ12.7x 7.5
Heat Exchanger
2 Row 16 Step 2 Row 28 Step
Refrigerant Control Unit
EEV
Freezer Oil Capacity
gal
0.16
cc
600
Refrigerant to be Charged (R410A)
oz
51.1
g
1450
Refrigerant to be Added (R410A)
oz/ft
0.16
g/m
15
0.16
15
Protection Device (OLP)
None
Cooling Test Condition
Indoor Unit : DB80°F WB67°F
Indoor Unit : DB26.7°C WB19.4°C
Heating Test Condition
Indoor Unit : DB70°F WB60°F
Indoor Unit : DB21.1°C WB15.6°C
Operation conditon range
cooling
indoor
61°F to 90°F approx.
16°C to 32°C approx.
Outdoor
14°F to 115°F approx.
-10°C to 46°C approx.
heating
indoor
80°F or less
27°C or less
Outdoor
5°F to 75°F approx.
-15°C to 24°C approx.
Φ0.7 x 1.8
Φ18 x 550
Rotary, G8T260FUAEW
Hermetic
2454W
FREOLα68ES-T
13.0
Φ5/8 x 24.6
Φ15.88x 7.5
EEV
0.18
700
51.1
1450
None
Outdoor Unit : DB95°F WB75°F
Outdoor Unit : DB35°C WB23.9°C
Outdoor Unit : DB47°F WB43°F
Outdoor Unit : DB8.3°C WB6.1°C
61°F to 90°F approx.
16°C to 32°C approx.
14°F to 115°F approx.
-10°C to 46°C approx.
80°F or less
27°C or less
5°F to 75°F approx.
-15°C to 24°C approx.
Cross-flow Propeller
Resin / Steel, AC
Resin / Steel, DC
40
0.3A 65W
93
0.6A 130W
X
X
34.6 25.1 12.2
X
X
880 638 310
28
13
52
114.6
1065x298x218
41.9x11.7x8.6
X
X
34.6 25.1 12.2
X
X
880 638 310
28
13
52
114.6
1065x298x218
2 Row 16 Step 2 Row 28 Step
Air Marketing Group LLC