Samsung Electronics
12-2-15 Compressor lock error
1. Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Yes
Restart after power off.
Is the lock error occurred again?
Is the interphase resistance value of
compressor (u
v, v
w, w
u) normal?
Is the connection cable for the
compressor and power terminal normal?
Exchange the PCB.
Terminate the service.
Exchange the compressor.
Is the compressor body and
interphase resistance insulated?
Exchange the compressor.
Correct the cable connection.
Yes
Yes
Yes
No
No
No
No
Troubleshooting
12-17
Содержание AQV09VBA Series
Страница 18: ...Samsung Electronics 4 1 4 Disassembly and Reassembly Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER ...
Страница 28: ...MEMO Samsung Electronics 4 11 ...
Страница 29: ...Samsung Electronics 5 1 5 Exploded Views and Parts List 5 1 Indoor Unit ...
Страница 31: ...Samsung Electronics 5 2 Outdoor Unit 5 3 ...
Страница 34: ...MEMO Samsung Electronics 5 6 ...
Страница 35: ...Samsung Electronics 5 7 5 4 Ass y Control Out AQV09VBCX DB93 05534E AQV12VBCX DB93 05534F ...
Страница 49: ...This Document can not be used without Samsung s authorization 7 2 Outdoor Unit Samsung Electronics 7 2 ...
Страница 50: ...7 3 Samsung Electronics MEMO ...
Страница 52: ...8 2 Outdoor Unit This Document can not be used without Samsung s authorization Samsung Electronics 8 2 ...
Страница 59: ...Samsung Electronics 11 1 2 Outdoor Unit Operating Instructions Air Outlet Air Inlet Rear Connection Valve 11 2 ...
Страница 86: ...Samsung Electronics SMPS AC COMMUNICATION SUB PCB INDOOR FAN CONTROL BUZZER CONTROL Block Diagram 13 2 ...
Страница 88: ...Samsung Electronics OUTDOOR FAN B D IGBT Block Diagram 13 4 DIODE IPM SMPS DC_LINK CAP ...