Samsung Electronics
3-2
Operating Instructions and Installation
1. A U TO MODE : In this mode, operation
mode(COOL, HEAT) is selected automati-
cally by the room temperature of initial
o p e r a t i o n .
∆
T= -2°, -1°C, 0°C+1°C+2°C
∆
T is controlled by setting temperature
up( )/down( ) key of re m o t e
c o n t ro l l e r
2. C O O L MODE : The unit operates accord i n g
to the diff e rence between the setting and
room temperature. (18°C~30°C)
3. H E AT MODE : The unit operates accord i n g
to the diff e rence between the setting and
room temperature.(16°C~30°C)
* P revention against cold wind : For about
3~5 minutes after initial operation, thermo
c o n t rol or “de-ice”, the indoor fan will
either not operate or operate very slowly,
then switch to the selected fan speed. This
period is to allow the indoor unit's heat-
exchanger to prewarm before emitting
warm air.
*High temperature release function : The
outdoor unit for and compressor ON/OFF
c o n t rol for safety operation, when the over-
heat is heat exchanger of indoor unit.
*De-ice : Deicing operation is controlled by
indoor unit's heat exchanger temperature
and accumulating time of compre s s o r ' s
o p e r a t i o n .
De-ice end by sensing of the pro c e s s i n g
time by de-ice Condition.
4. D RY MODE :
The unit operates in DRY m o d e .
*Co m p ressor ON/OFF Time is contro l l e d
compulsorily(can not set up the fan speed,
always bre e z e ) .
* P rotective function : Low temperature
release. (Prevention against fre e z e )
5. TURBO MODE : This mode is available in
A U TO, COOL, HEAT, DRY, FAN MODE.
When this button is pressed at first, the air
conditioner is operated “powerful” state for
30 minutes re g a rdless of the set tempera-
t u re, room temperature .
When this button is pressed again, or when
the operating time is 30 minutes, turbo
operation mode is canceled and returned to
the previous mode.
*But, if you press the TURBO button in DRY
or FAN mode that is changed with A U TO
mode automatically.
6 . S L E E P MODE : Sleep mode is available
only in COOL or HEAT mode.
The operation will stop after 6 hours.
*In COOL mode : The setting temperature
is automatically raised by 1°C each 1hour
When the temperature has been raised by
total of 2°C, that temperature is main-
t a i n e d .
*In HEAT mode : The setting temperature
is automatically droped by 1°C each 1hour.
When the temperature has been droped by
total of 2°C, that temperature is main-
t a i n e d .
7. FAN SPEED : Manual / Auto
Fan speed automatically varies depending
on both the diff e rence between setting and
the room temperature .
Room Temp
Tr
≥
21°C+
∆
T
21°C +
∆
T>Tr
Operation Type
Cool Operation (Set Temp:24°C+
∆
T)
Heat Operation (Set Temp : 22°C+
∆
T)
3-1-1 Name & Function of Key in remote controller
Содержание AQT24A1QE/B
Страница 2: ...Samsung Electronics Co Ltd DEC 1998 Printed in Korea Code No DB81 00029A 1...
Страница 4: ...1 2 Samsung Electronics MEMO...
Страница 8: ...Product Specifications 2 4 Samsung Electronics 2 3 3 b 18K BTU Front view Rear view 582 787 340...
Страница 9: ...2 5 Samsung Electronics 2 4 Pressure Graph 24K BTU 18K BTU...
Страница 10: ...2 6 Samsung Electronics MEMO...
Страница 28: ...4 5 Samsung Electronics MEMO...
Страница 38: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Страница 46: ...6 9 Samsung Electronics MEMO...
Страница 48: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 Main PCB B B B...
Страница 51: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Страница 54: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit PNA4612MOOXD...