Samsung Electronics
13-7 Installation Diagram of Indoor Unit and Outdoor Unit
13-7-1 Air-Purge Procedure
1) Connect each assembly pipe to the appropriate valve
on the outdoor unit and tighten the flare nut.
3) Open the valve of the low pressure side of
manifold gauge counter-clockwise.
4) Purge the air from the system using vacuum pump
for about 20 minutes.
– Make sure that pressure gauge show
-14.5psi(-0.1MPa, -76cmHg) after about 20 minutes.
– This procedure is very important in order to avoid
gas leak.
– Turn off the vacuum pump.
– Close the valve of the low pressure side of
manifold gauge clockwise.
– Remove the hose of the low pressure side
of manifold gauge.
7) Check for gas leakage.
- At this time, especially check for gas leakage from
the 3 way valve’s stem nuts, and from the service
port cap.
2) Connect the charging hose of low pressure side of
manifold gauge to the packed valve having a service
port as shown at the figure.
5) Set valve cork of both liquid side and gas side of
packed valve to the open position.
6) Mount the valve stem nuts and the service port cap
to the valve, and tighten them at the torque of
183kgf•cm with a torque wrench.
A
B
C
D
Outdoor unit
Indoor unit
Gas pipe side
Liquid pipe side
Vacuum Pump
A
(gas)
B
(liquid)
Valve stem
Stem cap
13-10
5/16 inch
(7.94mm)
8) For further detailed information how to check the low
pressure after installation,
Please refer to Page 3-1.
Содержание AQB18J6WC
Страница 16: ...Samsung Electronics 4 1 4 Disassembly and Reassembly Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER ...
Страница 24: ...MEMO Samsung Electronics 4 9 ...
Страница 25: ...Samsung Electronics 5 1 5 Exploded Views and Parts List 5 1 Indoor Unit ...
Страница 27: ...Samsung Electronics 5 2 Outdoor Unit 5 3 ...
Страница 30: ...MEMO Samsung Electronics 5 6 ...
Страница 31: ...Samsung Electronics 5 7 5 4 Ass y Control Out AQV18JAX DB93 04346B AQV24JAX DB93 04346A ...
Страница 34: ...This Document can not be used without Samsung s authorization 6 2 Outdoor Unit 6 2 Samsung Electronics ...
Страница 36: ...7 2 Outdoor Unit This Document can not be used without Samsung s authorization Samsung Electronics 7 2 ...
Страница 42: ...Samsung Electronics MEMO 9 3 ...
Страница 72: ...Samsung Electronics SMPS 485 COMMUNICATION SUB PCB INDOOR FAN CONTROL BUZZER CONTROL Block Diagram 12 2 ...
Страница 74: ...Samsung Electronics 12 4 OUTDOOR FAN B D IGBT DIODE IPM SMPS DC_LINK CAP ...