Samsung Electronics
No
No
Yes
Yes
Yes
11-2-2 The Outdoor unit power supply error
1. Checklist :
1) Are the input power voltage and the power connection correct?
2) Is there no Fuse short in the indoor unit and outdoor unit?
3) Is the cable connected correctly between the indoor unit and outdoor unit in order.
4) Is the wire connected correctly to the terminal block of the indoor unit and outdoor unit?
2. Troubleshooting procedure
No
No
Is the voltage of indoor unit
terminal block 1 and 2 correct
after power input?
Pull out the power cord
and execute the following step
after 30 seconds.
Is the outdoor unit normal?
Is the outdoor unit normal?
Is the reactor connected correctly?
Is the +, - of C102 short?
Is the R701 resistance of
indoor PCB 200Ω?
Is the indoor unit fuse normal?
Exchange the fuse.
Connect the reactor wire.
Disassemble the PCB
from the case.
Is there no error at
the insertion of PCB?
Exchange the PCB.
Exchange the fuse.
Normal Operation
Exit
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Exchange the PCB.
Exchange the PCB.
11-3
Troubleshooting
Are the BLDC FAN Wire
1 and 3 short?
Is the +,- of C102 short?
Exchange the BLDC FAN.
Exchange the PCB.
Air Marketing Group LLC
141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-1782 Fax: 201-782-1783 Web: www.amgair.com Email: [email protected]