2-4 Details for Operation Property
1 AUTO MODE : In this mode, operation mode
(COOL,HEAT) is selected automatically by the
room temperature of initial operation.
(Set Temp. : 24°C)
2 COOL MODE : The unit operates according to
the difference between the setting and room
temperature.(16°C ~ 30°C)
3 HEAT MODE : The unit operates according to
the difference between the setting and room
temperature.(16°C ~ 30°C)
*Prevention against cold wind : In order to prevent
the cool air from flowing out at the heat mode,
the indoor fan does not operate or orperates
very slowly in the following cases. At this time,
the indoor heat exchanger will be preheating.
- For 3~5 minutes after the initial operation
- For deicing operation
- The operation of an indoor fan in accordance with
the temperature of an indoor heat exchanger.
*High temperature release function: It is a function to
detect an outdoor overload by the sensor of an indoor
exchanger and to turn the outdoor fan or the compressor
ON/OFF for safety.
*Deice : Deicing opertion is controlled by indoor unit's
heat exchanger temperature and accumulating time of
compressor's operation. Deice ends by sensing of the
processing time by deice condition.
4 DRY MODE : Has 3 states, each determined by room
temperature.
The unit operates in DRY mode.
*Compressor ON/OFF time is controlled compulsorily
(can not set up the fan speed, always breeze)
*Protective function : Low temperature release.
(Prevention against freeze)
9 EVAP. CLEAN MODE : The unit operates according
to the below.
*When the air conditioner is turned off.
The Evaporator clean indicator on the indoor unit
display appears and the Evaporator cleaning function runs.
*When the air conditioner is turned on.
The Evaporator clean indicator on the indoor unit
display appears and the Evaporator cleaning function
runs after stopping the air conditioner operation.
*Evaporator cleaning time can vary, depending on the
previously used mode.
1) Auto(COOL),COOL,DRY MODE :
approximately 30 minutes.
2) Auto(HEAT),HEAT,FAN MODE :
approximately 15 minutes.
6 GOOD'SLEEP MODE : Default good'sleep time is set to
8 hours. But the good'sleep time can be set up to 12
hours, increasing in 30 minute unit up to first 3 hours and
in hourly unit after first 3 hours.
*Temperature/Fan speed/Air swing can be adjusted after
setting good'sleep in HEAT MODE.
*Temperature can be adjusted and the air conditioner
automatically adjusts Fan speed/Air swing after setting
good'sleep in COOL MODE.
7 FAN SPEED : Manual (3step),Auto (4 step)
Fan speed automatically varies depending on both the
difference between setting and the room temperature.
8 COMPULSORY OPERATION : For operating the air
conditioner without the remote control.
*The air conditioner starts up in the most suitable mode
for the room temperature.
5 TURBO MODE : This mode is available in AUTO,
COOL,HEAT,DRY,FAN MODE.
When this button is pressed at first, the air conditioner
is operated "powerful" state for 30 minutes regardless
of the set temperature, room termperature.
When this button is pressed again, or when the
operating time is 30 minutes, turbo operation mode is
canceled and returned to the previous mode.
*But, if you press the TURBO button in DRY or FAN
mode that is changed with AUTO mode automatically.
The temperature of indoor heat exchanger
indoor fan speed
below 28°C
off
28°C~below 34°C
LL speed
34°C~below 40°C
L speed
above 40°C
Setting speed
Option
Mode
Heat pump option selected
Auto mode
Cooling only option selected
Cooling mode
Samsung Electronics
-
7
Содержание AQ12 SER Series
Страница 11: ...Samsung Electronics 3 1 3 Disassembly and Reassembly Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER ...
Страница 21: ...Samsung Electronics 4 1 4 1 Setting Option Setup Method 4 Troubleshooting ...
Страница 22: ...4 2 Samsung Electronics 4 1 Setting Option Setup Method continue ...
Страница 43: ...8 1 2 Display Samsung Electronics Samsung Confidential 8 1 PCB Circuit Description 8 2 ...