background image

12_

 viewing

viewing your air conditioner 

CHECKING THE REMOTE CONTROL

You can activate the air conditioner by pointing the remote control away from it. When using the remote
control, always point it directly at the air conditioner.

Each time you press the button, a short beep will sound and a transmit indicator appears 
on the remote control display.

Remote Control display

Power

Turn on/off the air conditioner.

Mode

Set one of the 5 operating modes. 

(See pages 14~18 for instructions.)

Fan speed 

Y Z

Adjust how much air flows 

through the air conditioner with

the 4 different fan speeds such as 

Auto/Low/Medium/High.

Air swing 

Activate/Deactivate air flow blade 
movement automatically up and down.

Temp

UV

Increase/Decrease the temperature by 1˚C.

Set/Cancel

Set/Cancel the timer 

function.

Set the 

mode on.

Off Timer

Set the Off Timer on.
Adjust the timer for off timer.

Turbo

Operate in maximum fan speed to 
cool/warm quickly.

Smart Saver

Less energy usage makes your 

space cool between the temperature

range of 26ºC~30ºC.

On Timer

Set the On Timer on.

Adjust the timer for on timer.

Содержание AQ07R Series

Страница 1: ...sing this Samsung product To receive more complete service please register your product at www samsung com global register AQ07R Series AQ09 Series AQ12U Series AQ18U Series E R R DB98 30079A Vivaldi...

Страница 2: ...r not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than el...

Страница 3: ...help and information online at www samsung com What the icons and signs in this user manual mean WARNING Risk of death or serious personal injury CAUTION Potential risk of personal injury or material...

Страница 4: ...wer cable or loosened power receptacle t Potential risk of fire or electric shock Do not yank the power cable and touch the power plug with hands t Potential risk of fire or electric shock Do not cut...

Страница 5: ...event the allowable concentration from being exceeded t If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result Always make sure...

Страница 6: ...service technician Do not block or place items in front of the air conditioner Do not step hang onto or place heavy items on the air conditioner t Potential risk of personal injury Do not allow childr...

Страница 7: ...risk of fire or loss of property When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care t Wearing thick gloves can protect your hands Check for damages on the H Beam o...

Страница 8: ...in hose to the air conditioner for proper water drainage Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop o...

Страница 9: ...a e h t g n i n r u T 14 e d o m n o i t a r e p o g n i t c e l e S o t u A 4 1 l o o C 5 1 y r D 6 1 n a F 7 1 t a e H 8 1 n o i t c e r i d w o l f r i a e h t g n i t s u j d A 9 1 w o l f r i a...

Страница 10: ...Please read the user manual to get started and to make the best use of the air conditioner CHECKING THE INDOOR UNIT AND DISPLAY Carefully unpack your air conditioner and check the unit to make sure i...

Страница 11: ...button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing...

Страница 12: ...rating modes See pages 14 18 for instructions Fan speed Y Z Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto Low Medium High Air swing Activate Deacti...

Страница 13: ...e in the same space t If other electrical products operate by the remote control call your nearest contact center Inserting the batteries Correct disposal of batteries in this product Applicable in th...

Страница 14: ...air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote con...

Страница 15: ...e or decrease the desired temperature You can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan Y or Z butto...

Страница 16: ...ir conditioner operates in Dry mode and automatically adjust the fan speed to Auto e h t s s e r p u o y n e h W Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperatu...

Страница 17: ...he air conditioner operates in Fan mode and circulate the indoor air When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan Y or Z but...

Страница 18: ...set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan Y or Z button on the remote control to set the desired fan...

Страница 19: ...ate the air To keep the air ow direction in a constant position press the Air swing button on the remote control again Horizontal air ow Make sure one of the blade pins that stick out of the air ow bl...

Страница 20: ...r 30 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry F...

Страница 21: ...will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays...

Страница 22: ...3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditi...

Страница 23: ...onditioner is off For example If the On timer is set at 3 hours and the Off timer at 5 hours the air conditioner will turn off automatically 3 hours after the set time and then operate for next 2 hour...

Страница 24: ...while Off timer indicator is blinking You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4 Press the Set Cancel button on the r...

Страница 25: ...s e r u t a r e p m e t r u o y s e s i a r d n a y d o b r u o y s e x a l e R Wake up from mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh n i r e m i t f...

Страница 26: ...C t Smart Saver function is only available in Cool mode t When Smart Saving function is activated temperature range will be limited to 26 C 30 C t If the desired temperature is lower than 26 C turn of...

Страница 27: ...cleaned with a vacuum or by hand washing 1 Open the front panel Tightly grab front side of the front panel and lift up the panel to open Then slightly push the panel up until the panel is hanged over...

Страница 28: ...the hooks of the unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Bio filter color in sky blue out to remove it from the s...

Страница 29: ...e panel to open Then slightly push the panel up until the panel is hanged over the hooks of the unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and sli...

Страница 30: ...ies 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the elect...

Страница 31: ...at pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air conditioner does...

Страница 32: ...the Air filter every tw o weeks t Check if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change t Check if you selected Auto or Dry mode The air conditioner a...

Страница 33: ...o have either water blow off or drops on the floor HEATING 27 C or less 5 C to 24 C Internal protection triggers and the air conditioner will stop DRYING 18 C to 32 C 15 C to 43 C Condensation may occ...

Страница 34: ...IA KAZAHSTAN UZBEKISTAN UKRAINE LITHUANIA LATVIA ESTONIA 8 800 555 55 55 8 10 800 500 55 500 8 800 120 0 400 8 800 502 0000 8 800 77777 800 7267 800 7267 www samsung ru www samsung kz www samsung uz w...

Отзывы: