5 Troubleshooting
5-12
AP17K*/AP17J*
5-1-20 User Control Failure
Does the DC level change at
Pin 36 of IC201 when you
push the button S/W?
Yes
Check the button.
(SW201 ~ SW204)
No
Check IC201, CN2 and CN206.
RL601 operation is right?
Q601 base input is right?
Check 13V Line.
Check and replace Q601.
No
No
Yes
Check D-coil and TH601.
Yes
IC201 Pin 4 output is right?
Check and replace IC201.
Yes
No
Done
Check degaussing connector.
5-1-21 Degaussing Failure
Содержание AP17K series
Страница 7: ...2 Product Specifications 2 4 AP17K AP17J Memo ...
Страница 17: ...4 Alignment and Adjustments 4 8 AP17K AP17J Memo ...
Страница 36: ...AP17K AP17J 6 1 6 Exploded View and Parts List ...
Страница 37: ...6 Exploded View Parts List 6 2 AP17K AP17J Memo ...
Страница 55: ...Memo 7 Electrical Parts List 7 18 AP17K AP17J ...
Страница 56: ...8 Block Diagrams AP17K AP17J 8 1 ...
Страница 57: ...Memo 8 Block Diagrams 8 2 AP17K AP17J ...
Страница 59: ...9 PCB Diagrams 9 2 AP17K AP17J Memo ...