5 Troubleshooting
5-18
AP17K*/AP17J*
Improved focus?
Check focus leads from FBT
to CRT Socket.
Check the CRT Socket.
No
Aging monitor and check for focus
change.
Yes
Dynamic focus circuit is right?
Refer to 5-1-15 Dynamic
Focus Failure.
Replace the CRT and verify focus.
Yes
No
Adjust focus VR of FBT.
5-2-7 Poor Focus
5-2-8 Purity Failure
Purity is right?
Degaussing circuit is right?
Refer to 5-1-20 Degaussing Failure.
Replace CRT and verify purity.
Yes
No
No
Done
Yes
Degaussing