Samsung Electronics
3-9
3-3-2(c) Connecting the Assembly Cable.
3-3-2(d) Installing and Connecting the Indoor Unit Drain Hose
C a re must be taken when installing the drain hose for the indoor unit to ensure that any condensa -
tion water is correctly drained outside.l When passing the drain hose through the 65mm hole drilled
in the wall, check that none of the following situations occur.
To install the drain hose, proceed as follows.
1. If necessary, connect the 2-metre extension to the drain hose.
2 . If you are using the extension, insulate the inside part of the extension drain hose with a shield.
3. Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight.
4. Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as
shown in the illustrations above.
Operating Instructions and Installation
The outdoor unit is powered from the indoor unit via the assembly
cable. If the outdoor unit is more than five metres away from the
indoor unit, the cable must first be extended to a maximum of
ten metre s .
1 . Extend the assembly cable if necessary.
2 . Open the front grille by pulling on the tabs on the lower right and
left sides of the indoor unit.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and
connect the assembly cable to terminals 1 to 5.
• Each wire is labelled with the corresponding terminal number.
5 . Pass the other end of the cable through the 65mm hole in the wall.
6 . Replace the connector cover, carefully tightening the scre w.
7 . Close the front grille.
8 . For further details on how to plug the other end of the assembly
cable into the outdoor unit, refer to page 3-10.
The hose must
NOT slope upw
ards.
The hose will be fixed permanently into position once
the whole installation has been tested for gas leaks;
refer to page 16 for further details.
The end of the drain
hose must NOT be
placed in water.
Do NOT bend the
hose in different
directions.
Keep a clearance of at
least 5cm between the
end of the hose and the
ground.
Do NOT place the end
of the drain hose in a
hollow.
Shield
Drain hose
Extension drain hose
Содержание AM14A1E07
Страница 3: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit AM20A1 B1 E08 AM20A1 B1 E06 AM14A1 B1 E07...
Страница 4: ...Samsung Electronics 9 2 9 2 Outdoor Unit UM20A1 B1 E3 UM14A1 B1 E2...
Страница 6: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 Main PCB INDOOR UNIT 8 1 1 AM14A1 B1 E07 DB93 10603A...
Страница 8: ...Samsung Electronics 8 3 8 1 2 AM20A1 B1 E08 DB93 00072A PCB Diagrams...
Страница 10: ...Samsung Electronics 8 5 8 1 3 AM20A1 B1 E06 DB93 10628A PCB Diagrams...
Страница 12: ...Samsung Electronics 8 7 8 2 PCB OUTDOOR UNIT 8 2 1 UM14A1 B1 E2 DB93 10618A UM20A1 B1 E3 DB93 10617A...
Страница 19: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit 6 1 a AM20A1 B1 E08 AM14A1 B1 E07...
Страница 21: ...Samsung Electronics 6 3 Exploded Views and Parts List 6 1 b AM20A1 B1 E06...
Страница 23: ...Samsung Electronics 6 5 6 2 Outdoor Unit UM20A1 B1 E3 9 9 1 9 5 6 2 a UM20A1 B1 E3...
Страница 25: ...Samsung Electronics 6 7 6 2 b UM14A1 B1 E2 Exploded Views and Parts List...
Страница 71: ...Samsung Electronics 2 5 2 3 2 b UM20A1 B1 E3 Product Specifications...
Страница 72: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit 10 1 1 AM14A1 B1 E07...
Страница 73: ...Samsung Electronics 10 2 10 1 2 AM20A1 B1 E06...
Страница 74: ...Samsung Electronics 10 3 10 2 1 UM20A1 B1 E3 UM14A1 B1 E2 10 2 Outdoor Unit...