Drain pipe and Drain Hose Installation
1. Install the drain hose as short as possible.
• Give a 10mm slant to the drain hose for proper drainage of
condensate.
• Secure the drain hose with the cable-tie not to be separated
from the unit.
• The drain pump connection port is used when using a drain
pump.
NOTE
2. Insulate the drain hose and then fix it as a picture.
• Assemble flexible hose with clamps between indoor unit
and drain pipe.
• Flexible hose clamps should be assembled tightly to prevent
being loosen. If it is loosen, it may cause water drops.
• Drain pipe must be insulated after installation.
NOTE
3. When drain pump is used, insulate the drain hose according to the
figure below.
• Check if rubber ring is installed properly on the drain pump.
• Check if the cap drain well blocks the drain port of drain pan.
NOTE
Flexible hose
Clamp
Cable-tie
Insulation
Binding tape of insulation
protective cover
Insulated drain pipe
Insulated
drain pipe
Binding
tape (to be
purchased
separately)
Insulation protective
cover of drain pipe
Indoor unit
Hose
connector
Hose
Cable-tie
Binding
treatment
Drain pipe
Cable-tie
Fix firmly without clearance.
04
INST
ALLA
TION
English-21