Saf
ety

 Inf
ormation on Installation

Do not use the air conditioner in environments with 
hazardous substances or close to equipment that 
release free flames to avoid the occurrence of fires, 
explosions or injuries.

Our units must be installed in compliance with the 
space specifications presented in the installation 
manual in order to ensure accessibility from both sides 
and allow repairs or maintenance operations to be 
carried out. 
The unit’s components must be accessible and easy to 
disassemble without endangering people and objects. 
For this reason, where it is not observed as indicated 
into the Installation Manual, the cost necessary 
to reach and repair the unit (in safety, as required 
by current regulations in force) with slings, trucks, 
scaffolding or any other means of elevation won’t be 
considered in-warranty and charged to end user.

Power supply line, fuse or circuit 

breaker

  WARNING

Always make sure that the power supply is compliant 
with current safety standards. Always install the air 
conditioner in compliance with current local safety 
standards.

Always verify that a suitable grounding connection is 
available.

Verify that the voltage and frequency of the power 
supply comply with the specifications and that the 
installed power is sufficient to ensure the operation of 
any other domestic appliance connected to the same 
electric lines.

Always verify that the cut-off and protection switches 
are suitably dimensioned.

Verify that the air conditioner is connected to the 
power supply in accordance with the instructions 
provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, 
section of leads, protections…) are compliant with 
the electric specifications and with the instructions 
provided in the wiring scheme. Always verify that all 
connections comply with the standards applicable to 
the installation of air conditioners.

Devices disconnected from the power supply should 
be completely disconnected in the condition of 
overvoltage category.

Be sure not to perform power cable modification, 
extension wiring, and multiple wire connection.

 

– It may cause electric shock or fire due to poor 

connection, poor insulation, or current limit override.

 

– When extension wiring is required due to power 

line damage, refer to Step 14  Optional: Extending 
the power cable in the installation manual.

  CAUTION

Make sure that you earth the cables.

Do not connect the earth wire to the gas pipe, water 
pipe, lighting rod or telephone wire. If earthing is not 
complete, electric shock or fire may occur.

Install the circuit breaker.

If the circuit breaker is not installed, electric shock or 
fire may occur.

Make sure that the condensed water dripping from the 
drain hose runs out properly and safely.
Install the power cable and communication cable of 
the indoor and outdoor unit at least 1m away from the 
electric appliance.
Install the indoor unit away from lighting apparatus 
using the ballast.

If you use the wireless remote control, reception error 
may occur due to the ballast of the lighting apparatus.

Do not install the air conditioner in following places.

Place where there is mineral oil or arsenic acid. Resin 
parts flame and the accessories may drop or water 
may leak. The capacity of the heat exchanger may 
reduce or the air conditioner may be out of order.

The place where corrosive gas such as sulphuric acid 
gas generates from the vent pipe or air outlet.

The copper pipe or connection pipe may corrode and 
refrigerant may leak.

The place where there is a machine that generates 
electromagnetic waves. The air conditioner may not 
operate normally due to control system.

The place where there is a danger of existing 
combustible gas, carbon fibre or flammable dust.

The place where thinner or gasoline is handled. Gas 
may leak and it may cause fire.

Содержание AJ035NB1DEH/SA

Страница 1: ...rconditioner User Installation manual AJ NB1DEH Thank you for purchasing this Samsung air conditioner Before operating this unit please read this user manual carefully and retain it for future referen...

Страница 2: ...ating temperature and humidity 12 Cleaning and Maintenance 13 Cleaning and Maintaining 13 Cleaning the indoor unit exterior 13 Cleaning the outdoor unit heat exchanger 13 Cleaning the air filter 14 Pe...

Страница 3: ...ir supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal Safety Information on...

Страница 4: ...WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage Follow directions...

Страница 5: ...his may result in electric shock or fire Neverinstall the outdoorunit in a location such as on a high external wall where it could fall If the outdoor unit falls it may result in injury death or prope...

Страница 6: ...eakeris damaged contact yournearest service centre Do not pull orexcessively bend the powerline Do not twist ortie the powerline Do not hook the powerline overa metal object place a heavy object on th...

Страница 7: ...sed to salt in the air please contact your nearest service centre Do not touch the circuit breakerwith wet hands This may result in electric shock Do not turn the airconditioneroff with the circuit br...

Страница 8: ...he powerby unplugging the powerplug and turning the circuit breakeroff and then contact yournearest service centre Failing to do so may result in electric shock or fire Do not attempt to repair disass...

Страница 9: ...to the remote controllerand do not disassemble the remote controller Do not touch the pipes connected with the product This may result in burns or injury Do not use this airconditionerto preserve pre...

Страница 10: ...ire CAUTION Take care when cleaning the surface of the heat exchangerof the outdoor unit since it has sharp edges To avoid cutting your fingers wear thick cotton gloves when cleaning it This should be...

Страница 11: ...the model and the panel type 02 01 04 05 03 01 Display 02 Remote control sensor 03 Airflow blade 04 Wind Free panel You can use the Wind Free Cooling function when the Cool Dry orFan mode is running R...

Страница 12: ...ry mode 18 C to 32 C CAUTION If you use the air conditioner at a relative humidity above 80 it may cause a formation of condensation and a leakage of water on the floor The rated heating capacity is b...

Страница 13: ...es Do not attach any stickers on the surfaces because this may cause damage When you clean the heat exchanger on the indoor unit you need to disassemble the indoor unit Therefore you must contact the...

Страница 14: ...grille with a hand to prevent dropping from the opening of the front grille NOTE When removing the grill completely unhook the safety hooks on both sides of the grill 1 Detaching the air filter PUSH...

Страница 15: ...dries in a humid area it may produce offensive odours Clean it again and dry it in a well ventilated area The cleaning period may differ depending on the usage and environmental conditions so clean t...

Страница 16: ...ir filter be sure to reset the filter cleaning reminder as follows Indoor unit with the wired remote control Press the Filter Reset button Indoor unit with the wireless remote control Press the Option...

Страница 17: ...d Replace the remote control batteries At least once a year Outdoor unit Clean the heat exchanger on the outside of the unit Once every 4 months Required Clean the heat exchanger on the inside of the...

Страница 18: ...re does not change Check whether the Fan mode is running In the Fan mode the air conditioner controls the set temperature automatically and you cannot change the set temperature Warm air does not come...

Страница 19: ...he Cool mode cool air does not come out if the set temperature is higher than the current temperature Remote control Press the Temperature button repeatedly until the set temperature minimum 18 C is s...

Страница 20: ...or if there is a smell entering from outside ventilate the room properly If both indoor temperature and indoor humidity are high operate the air conditioner in the Clean or Fan mode for1 to 2 hours If...

Страница 21: ...at least once every12 months according to regulation No 517 2014 This activity must be covered by qualified personnel only In the case of the situation above the installer or authorized person with r...

Страница 22: ...talledinareasusedforlaundry Donotusetheunitsifdamaged Ifproblemsoccur switch theunitoffanddisconnectitfromthepowersupply In orderto prevent electric shocks fires or injuries always stop the unit disab...

Страница 23: ...s verify that all connections complywith the standards applicable to the installation of air conditioners Devices disconnected from the power supply should be completely disconnected in the condition...

Страница 24: ...or unit on a ceiling that can support its weight Maintain sufficient clearance around the indoorunit Before installing the indoorunit be sure to check whetherthe chosen location is well drained The in...

Страница 25: ...eiling opening dimension 249 Space of suspension bolts 440 Ceiling opening dimension 1036 Space of suspension bolts Model AJ026NB1DEH AJ035NB1DEH Chassis Medium Net dimension W D H mm 970 X 410 X135 L...

Страница 26: ...C and humidity is over 80 you must apply an extra10 mm thick polyethylene insulation or a similartype of insulation to the body of the indoor unit Cut away the part where pipes are pulled out forthe i...

Страница 27: ...the false ceiling to allow access formaintenance orrepairs to the drainage pipe connection the refrigerant pipe connection orto remove the unit if necessary 5 Hang the indoor unit to the suspension b...

Страница 28: ...flaring tool and pipe holder 2 If you wish to shorten the pipes cut them with a pipe cutter ensuring that the cut edge remains at a 90 angle to the side of the pipe Referto the illustrations below fo...

Страница 29: ...e that there are no cracks orwaves on the bent area 5 It would be necessary to double the insulation thickness 10 mm or more to prevent condensation even on the insulatorwhen if the installed area is...

Страница 30: ...pipes and drain hose avoiding compressing the insulation too much 3 Finish wrapping insulating tape around the rest of the pipes leading to the outdoorunit 4 The pipes and electrical cables connectin...

Страница 31: ...the same insulation that is used for high humidity conditions Geological condition High humidity locations such as shorelines hot springs lake or riversides and ridges when part of the building is cov...

Страница 32: ...ight within 300 mm from the drain hose port If it is raised higherthan 550 mm there may be water leaks Band joint 300 mm or less 20 mm or more Ceiling 1 100 or more 300 to 550 mm Drain hose Do not giv...

Страница 33: ...ent if the horizontal drain pipe is in proper slope Step11 Performing the drainage test 1 Do a leak test at the connection part of the flexible hose and the drain pipe a Connect a general hose to the...

Страница 34: ...age check is completed and the condensed water remains on the drain pan remove the water Step12 Connecting the powerand communication cables CAUTION Always rememberto connect the refrigerant pipes bef...

Страница 35: ...r braid copper of FROHH2R type Connect the power cable to the auxiliary circuit breaker An all pole disconnection from the power supply must be incorporated in the fixed wiring Step13 Optional WiringW...

Страница 36: ...same location The compression dimension should be 8 0 Compression dimension After compressing it pull both sides of the wire to make sure it is firmly pressed Compress it 4 times 5 mm Compress it 4 ti...

Страница 37: ...remote control and then insert them again b While holding down the High Temp and Low Temp buttons simultaneously insert the batteries into the remote control c Make sure that you are entered to the m...

Страница 38: ...ntrol display 3 Set the SEG4 and SEG5 values a Set the SEG4 value by pressing the Low Fan button repeatedly until the value you want to set appears on the remote control display SEG4 b Set the SEG5 va...

Страница 39: ...repeatedly until the value you want to set appears on the remote control display When you press the Low Fan or High Fan button values appear in the following order SEG10 8 Press the Mode button Heat...

Страница 40: ...lowing order SEG15 12 Press the Mode button Cool and Off appear on the remote control display 13 Set the SEG16 and SEG17 values a Set the SEG16 value by pressing the Low Fan button repeatedly until th...

Страница 41: ...trol display SEG21 b Set the SEG22 value by pressing the High Fan button repeatedly until the value you want to set appears on the remote control display When you press the Low Fan or High Fan button...

Страница 42: ...press the Power button again 5 Check whetherthe air conditioner operates in accordance with the option values you have set a Reset the indoor unit by disconnecting and then reconnecting the power cab...

Страница 43: ...ess 0 9 100 digit 0 9 10 digit 0 9 A single digit 1 Main address setting mode Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE Reserved Setting RMC address Reserved Group channel 16 Group addr...

Страница 44: ...Setting the output of external control S Plasma ion Buzzer Control Hours of filter usage SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 3 Individual control with remote control Heating setting compensation offs...

Страница 45: ...SEG9 SEG10 SEG11 SEG12 Explanation Page Use of drain pump Reserved Reserved Reserved Remote control Indication and details Indication Details Indication Details Indication Details 1 0 Disuse 0 Slave 1...

Страница 46: ...channel1 0 Default 1 0 Default Maintain blade status in wind free mode 0 Disuse 2 channel 2 1 1 Standard Turn out in 30 min without motion 2 Turn out in 60 min without motion 3 channel 3 3 Turn out i...

Страница 47: ...ption type 0 to F Tens position value 0 to 9 Units position value 0 to 9 New value 0 to F Example Changing the Buzzer control SEG17 option of the installation options to1 disuse Option SEG1 SEG2 SEG3...

Страница 48: ...or Short or Open E122 X X X Error on Eva out sensor Short or Open E123 Indoorfan error E154 X X X X Error on outdoortemperature sensor Short or Open E221 X X X Error on cond sensor E237 Erroron discha...

Страница 49: ...ump down_1 prevetion control E413 Compressor down due to low pressure sensor prevention control_1 E410 Simultaneous opening of cooling heating MCU SOLvalve 1st detection E180 Simultaneous opening of c...

Страница 50: ...QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT AUSTRALIA 1300 362 603 Other www samsung com au support VIETNAM 1800 588 889 www samsung com vn support...

Отзывы: