19
English
Instal
lation Pr
oc
edur
e
Step 6 Connecting the refrigerant pipe
◆ AJ040/050TXJ2KG
1
Piping outside diameter
Indoor unit
Out unit
Power supply
Ø, V, Hz
Outside
diameter
Liquid Gas
AR07/09/12********,
AJ026/035TN*D*G AJ040TXJ2KG 1,220-240, 50
1/4"
3/8"
AR07/09/12********,
AJ016/020/026
/035TN*D*G
AJ050TXJ2KG 1,220-240, 50
1/4"
3/8"
AR18********,
AJ052TNJDKG
1/2"
NOTE
• This product requires no additional refrigerant charge
up to the maximum allowable pipe length.
Maximum allowable refrigerant charge amount
AJ040TXJ2KG/EU
980 g
AJ050TXJ2KG/EU
1180 g
• AJ040T
XJ2KG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ0**TNNDKG/AJ0**TNLDEG
Make at least one round:
It will reduce noise and vibration
2
Piping length and the height
1 Room
max
length
2 Room
total max
length
Max height
between
indoor unit
& outdoor
unit
Max height
between
indoor units
Dimension
20m
30m
15m
7.5m
Composition
A,B
A+B
(H)
(h)
◆ AJ052/068TXJ3KG
1
Piping outside diameter
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
AR07/09/12********,
AJ016/020/026
/035TN*D*G
AJ052TXJ3KG
AJ068TXJ3KG
1,220-240,
50
1/4"
3/8"
AR18********,
AJ052TN*D*G
1/2”
NOTE
• AJ052TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ052TNNDKG/AJ052TNMDEG
• AJ068TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ***TNJDKG
2
Piping length and the height
1 Room
max
length
3 Room
total max
length
Max height
between
indoor unit
& outdoor
unit
Max height
between
indoor units
Dimension
25m
50m
15m
7.5m
Composition
A,B,C
A+B+C
(H)
(h)
Main power switch
A
B
(h) (H)
C
Make at least one round:
It will reduce noise and vibration
A
B
(h) (H)
Main power switch