Installation Pr

oc

edur

e

Installation Procedure

Step 1  Checking and preparing 

accessories

The following accessories are supplied with the indoor 
unit. The type and quantity may differ, depending on the 
specifications.

Installation template

Dimension gauge

Insulation drain

Flexible hose

Rubber

Installation manual

Cable-tie

User manual

Step 2  Choosing the installation 

location

Installation location requirements

•  There must be no obstacles near the air inlet and 

outlet.

•  Install the indoor unit on a ceiling that can support its 

weight.

•  Maintain sufficient clearance around the indoor unit.
•  Before installing the indoor unit, be sure to check 

whether the chosen location is well-drained. 

•  The indoor unit must be installed such that it is beyond 

public access and is not touchable by users.

•  Rigid wall without vibration.
•  Where it is not exposed to direct sunshine.
•  Where the air filter can be removed and cleaned easily.

  CAUTION

•  As a rule, the unit cannot be installed at a height of 

less that 2.5m.

•  If you install the cassette or duct type indoor unit on 

the ceiling with humidity over 80%, you must apply 
extra 10mm of polyethylene foam or other insulation 
with similar material on the body of the indoor unit.

Содержание AJ NB1DEH Series

Страница 1: ...Airconditioner Installation manual AJ NB1DEH Thank you for purchasing this Samsung air conditioner Before operating this unit please read this manual carefully and retain it for future reference...

Страница 2: ...Cutting and flaring the pipes Step 7 Connecting the assembly pipes to the refrigerant pipes Step 8 Performing the gas leak test Step 9 Insulating the refrigerant pipes Step10 Installing the drain hos...

Страница 3: ...sedforlaundry Donotusetheunitsifdamaged Ifproblemsoccur switch theunitoffanddisconnectitfromthepowersupply In orderto prevent electric shocks fires or injuries always stop the unit disable the protect...

Страница 4: ...ays verify that all connections complywith the standards applicable to the installation of air conditioners Devices disconnected from the power supply should be completely disconnected in the conditio...

Страница 5: ...a ceiling that can support its weight Maintain sufficient clearance around the indoor unit Before installing the indoor unit be sure to check whetherthe chosen location is well drained The indoor uni...

Страница 6: ...ling 1150 Ceiling opening dimension 249 Space of suspension bolts 440 Ceiling opening dimension 1036 Space of suspension bolts Model AJ026NB1DEH AJ035NB1DEH Chassis Medium Net dimension W D H mm 970 X...

Страница 7: ...ty is over 80 you must apply an extra10 mm thick polyethylene insulation or a similartype of insulation to the body of the indoor unit Cut away the part where pipes are pulled out forthe insulating wo...

Страница 8: ...t space in the false ceiling to allow access for maintenance or repairs to the drainage pipe connection the refrigerant pipe connection orto remove the unit if necessary 5 Hang the indoor unit to the...

Страница 9: ...l and pipe holder 2 If you wish to shorten the pipes cut them with a pipe cutter ensuring that the cut edge remains at a 90 angle to the side of the pipe Referto the illustrations below for examples o...

Страница 10: ...4 Make sure that there are no cracks orwaves on the bent area 5 It would be necessary to double the insulation thickness 10 mm or more to prevent condensation even on the insulatorwhen if the install...

Страница 11: ...rain hose avoiding compressing the insulation too much 3 Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit 4 The pipes and electrical cables connecting the indoo...

Страница 12: ...s below use the same insulation that is used for high humidity conditions Geological condition High humidity locations such as shorelines hot springs lake or riversides and ridges when part of the bui...

Страница 13: ...300 mm from the drain hose port If it is raised higherthan 550 mm there may be water leaks Band joint 300 mm or less 20 mm or more Ceiling 1 100 or more 300 to 550 mm Drain hose Do not give the hose...

Страница 14: ...nstall airvent if the horizontal drain pipe is in proper slope Step11 Performing the drainage test 1 Do a leak test at the connection part of the flexible hose and the drain pipe a Connect a general h...

Страница 15: ...is completed and the condensed water remains on the drain pan remove the water Step12 Connecting the powerand communication cables CAUTION Always rememberto connect the refrigerant pipes before perfor...

Страница 16: ...inum polyester braid copper of FROHH2R type Connect the power cable to the auxiliary circuit breaker An all pole disconnection from the power supply must be incorporated in the fixed wiring Step13 Opt...

Страница 17: ...n The compression dimension should be 8 0 Compression dimension After compressing it pull both sides of the wire to make sure it is firmly pressed Compress it 4 times 5 mm Compress it 4 times 5 mm Met...

Страница 18: ...ies from the remote control and then insert them again b While holding down the High Temp and Low Temp buttons simultaneously insert the batteries into the remote control c Make sure that you are ente...

Страница 19: ...y 3 Set the SEG4 and SEG5 values a Set the SEG4 value by pressing the Low Fan button repeatedly until the value you want to set appears on the remote control display SEG4 b Set the SEG5 value by press...

Страница 20: ...h Fan button repeatedly until the value you want to set appears on the remote control display When you press the Low Fan or High Fan button values appear in the following order SEG10 8 Press the Mode...

Страница 21: ...r SEG15 12 Press the Mode button Cool and Off appear on the remote control display 13 Set the SEG16 and SEG17 values a Set the SEG16 value by pressing the Low Fan button repeatedly until the value you...

Страница 22: ...e remote control display SEG21 b Set the SEG22 value by pressing the High Fan button repeatedly until the value you want to set appears on the remote control display When you press the Low Fan or High...

Страница 23: ...Power button again 5 Check whetherthe air conditioner operates in accordance with the option values you have set a Reset the indoor unit by disconnecting and then reconnecting the power cable of the i...

Страница 24: ...No Main address 0 9 100 digit 0 9 10 digit 0 9 A single digit 1 Main address setting mode Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE Reserved Setting RMC address Reserved Group channel 1...

Страница 25: ...output of external control S Plasma ion Buzzer Control Hours of filter usage SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 3 Individual control with remote control Heating setting compensation offset Dew remov...

Страница 26: ...n SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation Page Use of drain pump Reserved Reserved Reserved Remote control Indication and details Indication Details Indication Details Indication Details 1 0 Disu...

Страница 27: ...Default 1 0 Default Maintain blade status in wind free mode 0 Disuse 2 channel 2 1 1 Standard Turn out in 30 min without motion 2 Turn out in 60 min without motion 3 channel 3 3 Turn out in 120 min wi...

Страница 28: ...tails 0 D Option type 0 to F Tens position value 0 to 9 Units position value 0 to 9 New value 0 to F Example Changing the Buzzer control SEG17 option of the installation options to1 disuse Option SEG1...

Страница 29: ...Short or Open E122 X X X Error on Eva out sensor Short or Open E123 Indoorfan error E154 X X X X Error on outdoortemperature sensor Short or Open E221 X X X Error on cond sensor E237 Error on discharg...

Страница 30: ...oor sump down_1 prevetion control E413 Compressor down due to low pressure sensor prevention control_1 E410 Simultaneous opening of cooling heating MCU SOLvalve 1st detection E180 Simultaneous opening...

Страница 31: ...31 English Appendix Memo...