Troubleshooting
4-12
Samsung Electronics
4-3-5 External Sensor Error (Error Code: E221, E231, E251, E320)
1. Test Item
1) Check the connection of the temperature sensor connector.
2) Check the resistance value of the temperature sensor.
2. Check
procedure
Error Code
Description
E221
Error of the temperature sensor of the outdoor unit
E231
Error of the COND. sensor of the outdoor unit
E251
Error of the discharge sensor of the outdoor unit
E320
Error of the OLP sensor of the outdoor unit
Power OFF
Is the temperature sensor connector
reconnected?
No
Yes
Yes
Replace the temperature sensor,
ױ
Power ON.
ױ
After confirming the state is normal, end the service.
No
Is the temperature
sensor-measuring resistance similar to the
table on the left?
After confirming the state is normal,
end the service.
No
Yes
Replace the outdoor unit PBA.
ױ
Power is on.
ױ
After confirming the state is
normal, end the service.
(Example) COND. sensor/outdoor unit temperature sensor measuring resistance value by temperature: E231, E221
(Example) OLP sensor/discharge temperature sensor measuring resistance value by temperature: E320, E251.
Current tem-
perature (°C)
Resistance
(KΩ)
Current tem-
perature (°C)
Resistance
(KΩ)
70
4
20
10
60
5
10
20
50
6
0
30
40
7
-10
40
30
8
Current tem-
perature (°C)
Resistance
(KΩ)
Current tem-
perature (°C)
Resistance
(KΩ)
80
40
30
180
70
50
20
220
60
60
10
320
50
90
0
550
40
110
Is the temperature sensor connector
connected?
e.g.) Room temperature: 26
ఁ
- Resistance: 10.28 KΩ
e.g.) Room temperature: 21
ఁ͑
- Resistance: 205.4 KΩ
Does the same error occur again
after power is on?