Samsung Electronics
13
No
Parts
Procedure
Remark
1
Panel
1) Remove 4 cover screws from the Hydro Unit.
(Use + Screw Driver)
2
Controller
&
Manometer
1) Remove 3 screws from it.
(Use + Screw Driver)
2) Remove pressure sensor by adjustable wrench.
(Use adjustable wrench-230kgf·cm)
3) Pull the manometer out.
4) Push the 2 hooks of cover.
5) Pull the bottom of remocon body up.
3-1 Hydro Unit
AEN160YD
∗
/AEN080YD
∗
Be sure that the power switch is in the OFF and the power source cord shall be unplugged prior to disassembly and reassembly works.