Installing and Connecting the Outdoor Unit Drain Hose
Fixing the Unit in Position
The outdoor unit must be installed on a rigid and stable base to
avoid any increase in the noise level and vibration, particularly
if the outdoor unit is to be installed close to a neighbour.
If it is to be installed in a location exposed to strong winds or at a
height, the unit must be fixed to an appropriate support
(wall or ground).
1
Position the outdoor unit so that the air flow is directed towards the
outside, as indicated by the arrows on the top of the unit.
2
Attach the outdoor unit to the appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.
❈
Certainly fix up its rubber leg, in order to prevent its vibration and noise.
I
NSTALLING THE
O
UTDOOR
U
NIT
When using the air conditioner in the heating mode,
ice may accumulate. During de-icing, the condensed water must be
drained off safely. Consequently, you must install a drain hose
on the outdoor unit, following the instructions below.
1
Insert the drain plug into the hole 1 on the underside of the outdoor unit.
2
Connect the drain hose to the drain plug.
➢
Inside diameter of drain hose is 18mm ( in).
3
Ensure that the drained water runs off correctly and safely.
Hole 1
64
45
660 mm (26 in)
335 mm
(13 in)
16
3
Rubber Leg
E-
39
ENGLISH