background image

E-

5

Indicator

Anion Indicator

Filter Reset Button & Indicator

Anion Button

Clean level Indicator

Operating Mode Indicator

Contamination Level Indicator

Contamination Level Indicator 
-     

Classifies the various contaminants in the indoor air, as Odor, Mote and Dust, 
and up to 5 levels can be displayed.

-     

Green indicates that the indoor air is clean. Red means that the indoor 
air is contaminated.

-

During the first two minutes after the air cleaner is turned on, the contamination level 
will move up and down because the sensor will be in the 
process of analyzing the contamination level of the indoor air. 
So it is recommended that you check the contamination level 
in 2 minutes.

N

N

N

N

o

o

o

o

tt

tt

e

e

e

e

Power Button

Clean Level Selection Button

Operating Mode Selection Button

Control Panel

Содержание AC340B

Страница 1: ...Air Cleaner E DB98 13335A 1 OWNER S INSTRUCTIONS AC340B AC340BR AC340BG ...

Страница 2: ...ake sure that there are no obstacles near the air inlet and outlet of the product If a strange noise burning smell or smoke come from the product immediately disconnect the power supply and consult an authorized service personnel Do not use this product for other purposes Do not spill any kind of liquids into the product Do not place containers containing liquid substances on top of the product Do...

Страница 3: ...R Selecting the Automatic Mode 7 Selecting the Pollen Mode 8 Selecting the Sleep Mode 9 Selecting the Odor Mode 10 OTHER FUNCTIONS Generating Anions 11 Adjusting the Clean Level Fan Speed 12 RECOMMENDATIONS FOR USE Operating Recommendations 13 Cleaning the Air Cleaner 14 Solving Common Problems 17 TECHNICAL SPECIFICATIONS ...

Страница 4: ...ower plug Pre filter Ionizer Electrostatic filter Nano silver formula TiO2 photocatalyst filter Anion generator Anti bacterial fan Metal filter Washable Filter Section Recovery Filter Section 8 Step Cleaning System Main Unit The Metal filter is coated with the Nano silver particles N N N No o o ot t t te e e e ...

Страница 5: ...ed Green indicates that the indoor air is clean Red means that the indoor air is contaminated During the first two minutes after the air cleaner is turned on the contamination level will move up and down because the sensor will be in the process of analyzing the contamination level of the indoor air So it is recommended that you check the contamination level in 2 minutes N N N No o o ot t t te e e...

Страница 6: ...ll help you take full advantage of the product s features The booklet is organized as follows The following figures are shown from page 4 to 5 View of the Unit They will help you find the buttons and understand the symbols that are displayed In the manual you will find a series of step by step procedures for each function available Three types of symbols are used to help you understand the illustr...

Страница 7: ...not move 1 If the is not displayed on the display select the Auto mode by pressing the button until it is displayed on the display of the air cleaner Result The air cleaner beeps The air cleaner operates in the Auto mode 2 To adjust the clean level refer to page 12 To adjust the generating anions refer to page 11 3 If necessary press the Power button Result The Power indicator on the display comes...

Страница 8: ...flow blade moves automatically 1 If the is not displayed on the display select the Pollen mode by pressing the button until it is displayed on the display Result The air cleaner beeps The air cleaner operates in the Pollen mode 2 To adjust the clean level refer to page 12 To adjust the generating anions refer to page 11 3 If necessary press the Power button Result The Power indicator on the displa...

Страница 9: ...is displayed on the display Result The air cleaner beeps The air cleaner operates in the Sleep mode 2 To adjust the clean level refer to page 12 To adjust the generating anions refer to page 11 3 If necessary press the Power button Result The Power indicator on the display comes on The air cleaner runs in the Auto Mode The air cleaner makes a ringing sound You can change modes at any time N N N No...

Страница 10: ...automatically and the air flow blade moves automatically 1 If the is not displayed on the display select the Odor mode by pressing the button until it is displayed on the display Result The air cleaner beeps The air cleaner operates in the Odor mode 2 To adjust the clean level refer to page 12 To adjust the generating anions refer to page 11 3 If necessary press the Power button Result The Power i...

Страница 11: ...y press the Power button Result The Power indicator on the display comes on The air cleaner runs in the Auto Mode The air cleaner makes a ringing sound If you wish to turn off the Anion Generation function press the button again Result The Anion Indicator disappears on the display The air cleaner stops generating anions into the indoor air 3 Anions are ultra fine particles charged negatively in th...

Страница 12: ...es in the clean level that was selected 2 If necessary press the Power button Result The Power indicator on the display comes on The air cleaner runs in the Auto Mode The air cleaner makes a ringing sound If you wish the air cleaner to automatically adjust the clean level for you press the button until the Auto mode is selected Result The clean level that was selected is canceled The air cleaner o...

Страница 13: ...r If the light on the Wash indicator comes on the washable filters must be cleaned The washable filters must be cleaned more often in environments that include large amounts of dust in the air Closing the air flow blade If you want to close the air flow blade use the Power button on the control panel Do not close the air flow blade with your hands ...

Страница 14: ...p and then separate it from the unit N N N No o o ot t t te e e e If the lens of the Dust Sensor is cleaned with a sharp or rough object the lens is damaged so the Dust Sensor may not work properly N N N No o o ot t t te e e e You must clean the lens of the Dust Sensor every six months However this may vary according to the time and place that the air cleaner was operated So the air cleaner must b...

Страница 15: ...t also has the function of sterilizing virus or bacteria in the air in your room You must clean the Washable Filters every 3 months or whenever the Wash Indicator comes on The cleaning frequency of the Washable Filters may vary according to the time and place that the air cleaner is operated 1 Open the Filter Box and pull out the Washable Filter Section towards the direction of the arrow 2 Wash th...

Страница 16: ...tion towards in the direction of the arrow 2 Dry the Recovery Filter Section under the sunlight at least for 8 hours The more frequently you dry the photocatalyst filter under the sunlight the higher the filter efficiency would be You can purchase new photocatalyst filters in the authorized service center Recovery Filter Section Photocatalyst filter Don t wash the photocatalyst filter It must be d...

Страница 17: ...lean filters in the Filter Box Unpleasant odors can be detected coming from the air cleaner Check whether the air cleaner is operating in the Sleep Mode In the Sleep Mode the display automatically diminishes its brightness to ensure a comfortable sleeping setting The Display Brightness is too dim Check whether the lens of the Dust Sensor is unclean Check whether the filters in the Washable and Rec...

Страница 18: ...Technical Specifications E 18 Model AC340B AC340BR AC340BG 220 240V 50 60Hz Power Supply ...

Страница 19: ...E 19 Memo ...

Страница 20: ...ELECTRONICS Printed in Korea THIS AIR CLEANER IS MANUFACTURED BY ...

Отзывы: