Sound pressure level
Indoor :
PAC
Unit: dB(A)
Model
AC100KNPDEH/EU (ODU : AC100KXADEH/EU)
47
41
AC140KNPDEH/EU (ODU : AC140KXADGH/EU)
51
45
Note
* Specifications may be subject to change without prior notice
1) These operation values were obtained in an anechoic room.
2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.
3) Operation sound level may differ depending on operation and ambient conditions.
NC curve
NC 60
NC 55
NC 50
NC 45
NC 40
NC 35
NC 30
NC 25
NC 20
NC 15
63
125
250
500
1000
2000
4000
8000
Octave band center frequency(Hz)
0
5
10
15
20
25
30
35
40
45
50
55
60
Sound pressure level(dB)
1) AC100KNPDEH/EU (ODU : AC100KXADEH/EU)
NC 60
NC 55
NC 50
NC 45
NC 40
NC 35
NC 30
NC 25
NC 20
NC 15
63
125
250
500
1000
2000
4000
8000
Octave band center frequency(Hz)
0
5
10
15
20
25
30
35
40
45
50
55
60
Sound pressure level(dB)
2) AC140KNPDEH/EU (ODU : AC140KXADGH/EU)
6
Turbo
Med
Turbo
Med
Turbo
Med
Содержание AC100KNPDEH/EU
Страница 1: ...SINGLE Technical Data Book PAC for Europe R410A 50Hz HP Model AC KNPDEH EU AC KXAD H EU ...
Страница 2: ...History Version Date Remark Ver 1 0 Modification Release SINGLE PAC for Europe R410A 50Hz 16 07 15 ...
Страница 10: ...Dimensional drawing Outdoor AC140KXADGH EU 4 Ø 9 52 Ø 20 6 Ø 34 5 Ø 22 2 Ø15 88 ...
Страница 11: ...Electrical wiring diagram Indoor PAC AC100KNPDEH EU AC140KNPDEH EU 5 ...
Страница 12: ...Electrical wiring diagram Outdoor AC100KXADEH EU 5 ...
Страница 13: ...Electrical wiring diagram Outdoor AC140KXADGH EU 5 ...