27
Ins
tallation Pr
oc
edur
e
English
Model
AC052MNLDKH/EU
AC071MNLDKH/EU
Static
Pressure
Option Code for Indoor Unit
0≤ SP ≤3
01C07C-1C1924-
27343C-370000
01C07C-1C59D0-
274750-370005
3< SP ≤4
01C07C-1C1968-
27343C-370000
01C07C-1C5D21-
274750-370005
Model
AC052MNMDKH/EU AC060MNMDKH/EU AC071MNMDKH/EU
Static
Pressure
Option Code for Indoor Unit
0≤ SP ≤3
01B07C-1C50F1-
27343C-374000
01B07C-1C5436-
273C46-376000
01B07C-1C5436-
274750-376000
3< SP ≤6
01B07C-1C5488-
27343C-374000
01B07C-1C54AB-
273C46-376000
01B07C-1C54AB-
274750-376000
6< SP ≤9
01B07C-1C54ED-
27343C-374000
01B07C-1C581E-
273C46-376000
01B07C-1C581E-
274750-376000
9< SP ≤12
01B07C-1C5941-
27343C-374000
01B07C-1C5972-
273C46-376000
01B07C-1C5972-
274750-376000
12< SP ≤15
01B07C-1C59B3-
27343C-374000
01B07C-1C59C8-
273C46-376000
01B07C-1C59C8-
274750-376000
Model
AC090MNMDKH/EU
AC100MNMDKH/EU
Static
Pressure
Option Code for Indoor Unit
0≤SP≤4
01B07C-1C549F-
275A64-375020
01B07C-1C549F-
276470-375020
4<SP≤8
01B07C-1C5917-
275A64-375020
01B07C-1C5917-
276470-375020
8<SP≤12
01B07C-1C599C-
275A64-375020
01B07C-1C599C-
276470-375020
12<SP≤15
01B07C-1C5AE1-
275A64-375020
01B07C-1C5AE1-
276470-375020
Model
AC120MNMDKH/EU
AC140MNMDKH/EU
Static
Pressure
Option Code for Indoor Unit
0≤SP≤5.2
01B07C-1C5424-
277882-374048
01B07C-1C5424-
278CA0-374045
5.2<SP≤8
01B07C-1C5489-
277882-374048
01B07C-1C5489-
278CA0-374045
8<SP≤12
01B07C-1C54FE-
277882-374048
01B07C-1C54FE-
278CA0-374045
12<SP≤15
01B07C-1C5940-
277882-374048
01B07C-1C5940-
278CA0-374045
Model
AC052MNMSEH/EU
AC071MNMSEH/EU
Static
Pressure
Option Code for Indoor Unit
SP=3
01B07C-1D5561-
27343C-370000
01B07C-1D55B1-
27474B-370000
3< SP ≤6
01B07C-1D55E2-
27343C-370000
01B07C-1D5922-
27474B-370000
6< SP ≤9
01B07C-1D5963-
27343C-370000
01B07C-1D5997-
27474B-370000
9< SP ≤12
01B07C-1D59D9-
27343C-370000
01B07C-1D5D0B-
27474B-370000
12< SP ≤15
01B07C-1D5D3C-
27343C-370000
01B07C-1D5D6F-
27474B-370000
Model
AC100MNMSEH/EU
Static
Pressure
Option Code for Indoor Unit
SP=4
01B07C-1D5911-276470-370000
4< SP ≤8
01B07C-1D59C7-276470-370000
8< SP ≤12
01B07C-1D5D2E-276470-370000
12< SP ≤15
01B07C-1D5D7F-276470-370000
Model
AC120MNMSEH/EU
Static
Pressure
Option Code for Indoor Unit
SP=5.2
01B07C-1D547C-277882-370040
5.2< SP ≤8
01B07C-1D54CC-277882-370040
8< SP ≤12
01B07C-1D5910-277882-370040
12< SP ≤15
01B07C-1D5974-277882-370040
NOTE
•
represents E. S. P(External Static Pressure) range
of factory setting.
You don’t have to adjust the fan speed separately
if the external static pressure of the installation
place is in
. When it is out of
, input the
appropriate option code.
•
If you input the inappropriate option code, error may
occur or the air conditioner is out of order. The option
code must be inputted correctly by the installation
specialist or service agent.